Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2016-01-18-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 01/18/2016
Date that the sample was received by the laboratory/organization performing the testing: 01/20/2016
The quantity of what the sample constitutes: 2
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden Wire
Comments: Unknown
Reel/Coil/Pack Number(s): S333401 3 1 S333443 3 1
Number of Coils: 2
Group Number: 10837
Strand Diameter: .6 in
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0587215 S0594715
Mfg. Lot Number(s): NA
Manufacturer(s): Sumiden
DIME Test ID: 2016-01-18-1-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 01/25/2016
Date Tested: 01/21/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
2
|
Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) | .208 | .197 | .197 | .197 | .197 | .197 | .197 | 0.217 | .208 | .197 | .198 | .197 | .197 | .197 | .197 | 0.217 |
| |
DIME Test ID: 2016-01-18-1-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/25/2016
Date Tested: 01/21/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: 916-227-7257
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
2
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | SO587215 | S333401-3-1 | 0.217 | 60565 | 54825 | 28.1 | 2.05 | Brian | SO594715 | S333443-3-1 | 0.217 | 59753 | | 27.7 | 1.71 | Brian |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|