DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 034J5004 Cty SAC Rte 51 PM 0.24/0.24 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Kenneth Haas |
Date Reported: |
08/18/2023 |
|
Address: |
TL Number: |
204477 |
||
City: |
||||
Project Name: |
||||
Prime Contractor: Lamon Construction Co., Inc. |
||||
Sample Taken Date: |
07/21/2023 |
Mix Design: |
Elephant Armor |
|
Contractor: Unknown |
Location: |
|||
Structure unique identifier: |
||||
Structure name: Fort Sutter Viaduct Hinge 15R |
||||
Location of Pour: |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.01 | 12.63 | 52787 | 4180.0 | 1 |
2 | 4.02 | 12.69 | 46055 | 3629.0 | 1 |
3 | 4.02 | 12.69 | 52765 | 4157 | 1 |
DIME Test ID: 2023-07-21-22-1
Number of specimens: 3
Compressive strength (to nearest 10 psi): 3990
Age of specimen: 3 days
Certified By: Spencer Adams
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 4.02 | 12.69 | 56172 | 4426.0 | 4 |
2 | 4.02 | 12.69 | 62193 | 4900.0 | 4 |
3 | 4.02 | 12.69 | 57756 | 4550 | 2 |
DIME Test ID: 2023-07-21-22-2
Number of specimens: 3
Compressive strength (to nearest 10 psi): 4630
Age of specimen: 28 days
Certified By: Spencer Adams
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing