Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994549 DEA: 032G5204 EFIS: 0321000235
QA Service Level: 1
DIST-CO-RTE-PM: 03-NEV,PLA,SIE-20,49,80-VAR
Work Description: PLACE POLYESTER CONCRETE OVERLAY AND REPLACE JOINT SEALS.
Location Description: NEVADA, PLACER AND SIERRA COUNTIES AT VARIOUS LOCATIONS
Contractor Name: AMERICAN CIVIL CONSTRUCTORS WEST COAST LLC
Contractor Address: 2990 Bay Vista Court, Suite D, Benicia, CA 94510
Resident Engineer: Tad Sampson Structure Rep.: Jimmer Ross
DIME Sample ID: 2023-07-20-29
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 07/20/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/21/2023
The quantity of what the sample constitutes: 1 Tanker - 18 Totes
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification: 943817
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2023-07-20-29-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 10/02/2023
Date Tested: 07/28/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2023-07-20-29-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 10/02/2023
Date Tested: 10/02/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units
|
pounds/gallons
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2023-07-20-29-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 10/02/2023
Date Tested: 07/26/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted vendor's results.
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
6
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.488 in
|
Sample 1 Ultimate strength
|
8579.6 psi
|
Sample 1 Thickness
|
0.251 in
|
Sample 1 Area
|
0.1225 in^2
|
Sample 1 Ultimate Strength Actual
|
1051 lbs
|
Sample 1 percent elongation
|
19.3 %
|
Sample 1 Time
|
0 MM:SS
|
Sample 2 Width
|
0.488 in
|
Sample 2 Thickness
|
0.254 in
|
Sample 2 Area
|
0.124 in^2
|
Sample 2 Ultimate strength
|
8556.5 psi
|
Sample 2 Ultimate Strength Actual
|
1061 lbs
|
Sample 2 percent elongation
|
16.6 %
|
Sample 2 Time
|
0 MM:SS
|
Sample 3 Width
|
0.486 in
|
Sample 3 Thickness
|
0.259 in
|
Sample 3 Area
|
0.1259 in^2
|
Sample 3 Ultimate strength
|
8586.2 psi
|
Sample 3 Ultimate Strength Actual
|
1081 lbs
|
Sample 3 percent elongation
|
16.9 %
|
Sample 3 Time
|
0 MM:SS
|
Sample 4 Width
|
0.487 in
|
Sample 4 Thickness
|
0.275 in
|
Sample 4 Area
|
0.1339 in^2
|
Sample 4 Ultimate strength
|
8536.2 psi
|
Sample 4 Ultimate Strength Actual
|
1143 lbs
|
Sample 4 percent elongation
|
15.1 %
|
Sample 4 Time
|
0 MM:SS
|
Sample 5 Width
|
0.489 in
|
Sample 5 Thickness
|
0.257 in
|
Sample 5 Area
|
0.1257 in^2
|
Sample 5 Ultimate strength
|
8536.2 psi
|
Sample 5 Ultimate Strength Actual
|
1073 lbs
|
Sample 5 percent elongation
|
18.7 %
|
Sample 5 Time
|
0 MM:SS
|
Sample 6 Width
|
0.489 in
|
Sample 6 Thickness
|
0.262 in
|
Sample 6 Area
|
0.1281 in^2
|
Sample 6 Ultimate strength
|
8532.4 psi
|
Sample 6 Ultimate Strength Actual
|
1093 lbs
|
Sample 6 percent elongation
|
15.6 %
|
Sample 6 Time
|
0 MM:SS
|
Ultimate Strength Average
|
8555 psi
|
Percent Elongation Average
|
17 %
|
DIME Test ID: 2023-07-20-29-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 10/02/2023
Date Tested: 07/28/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination
|
43
|
DIME Test ID: 2023-07-20-29-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 10/02/2023
Date Tested: 07/26/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted vendor's results.
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1
|
24hr
|
Maximum applied load (P) for Sample 1
|
2171 lb
|
Span length for Sample 1
|
9 in
|
Break location for Sample 1
|
bond
|
Specimen defects/notes for Sample 1
|
no data
|
Surface type for Sample 1
|
SSD
|
Modulus of rupture (R) for Sample 1
|
1085.5 psi
|
Curing history for Sample 2
|
24hr
|
Maximum applied load (P) for Sample 2
|
1757 lb
|
Span length for Sample 2
|
9 in
|
Break location for Sample 2
|
bond
|
Specimen defects/notes for Sample 2
|
no data
|
Surface type for Sample 2
|
SSD
|
Modulus of rupture (R) for Sample 2
|
878.5 psi
|
Curing history for Sample 3
|
24hr
|
Maximum applied load (P) for Sample 3
|
2099 lb
|
Span length for Sample 3
|
9 in
|
Break location for Sample 3
|
bond
|
Specimen defects/notes for Sample 3
|
no data
|
Surface type for Sample 3
|
SSD
|
Modulus of rupture (R) for Sample 3
|
1049.5 psi
|
DIME Test ID: 2023-07-20-29-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 10/02/2023
Date Tested: 07/25/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted Vendor's Results
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid
|
153.9 mm
|
Room Temperature
|
77 f
|
Tare weight
|
no data
|
Initial weight
|
100.042 grams
|
Weight at 5 minutes
|
99.965 grams
|
Weight at 10 minutes
|
99.895 grams
|
Weight at 15 minutes
|
99.83 grams
|
Weight at 20 minutes
|
99.742 grams
|
Weight at 25 minutes
|
99.668 grams
|
Weight at 30 minutes
|
99.596 grams
|
Final weight
|
99.6 grams
|
Total weight loss
|
0.44 grams
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
Lid Factor
|
53.757 m^2
|
Volatile emission
|
23.761 grams/m^2
|