Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2016-01-06-3
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM2 - Type B Elastomeric Joint Seal
Sample Taken Date: 01/06/2016
Date that the sample was received by the laboratory/organization performing the testing: 01/12/2016
The quantity of what the sample constitutes: 600ft
A brief description of the sample: Joint Seal
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: D S Brown
DIME Test ID: 2016-01-06-3-1
Test Method: CTM 673-July 2012: Method of Determining Movement Rating of Type B1 and B2 Preformed Elastomeric Joint Seals
Verified Date: 02/01/2016
Date Tested: 01/13/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
UTM
|
11KIP
|
Temperature
|
72 ?F
|
Humidity
|
50 %
|
Load at W1
|
52.0636 lbs
|
Width at 4 x Load at W1
|
1.61495 in
|
Nominal Width
|
3.5 in
|
Measured Maximum Uncompressed Width
|
3.948 in
|
Measured Minimum Uncompressed Width
|
3.857 in
|
Minimum Uncompressed Width as Specified by the Manufacturer (MUWASBM)
|
3.86 in
|
Height of Contact Face
|
3.614 in
|
Spec Minimum Uncompressed Width
|
3.857 in
|
Length
|
no data
|
Area (5 Times of the Height of Contact Face)
|
18.07 sqin
|
Half of the Spec Minimum Uncompressed Width
|
1.93 in
|
85 Percent of the Spec Minimum Uncompressed Width
|
3.27845 in
|
3 Times of the Area
|
54.21 sqin
|
4 Times of the Load at W1
|
208.254 in
|
W1 (US Units)
|
3.278 in
|
W1 (Metric Units)
|
83.273 millimeters
|
W2 (US Units)
|
1.615 in
|
W2 (Metric Units)
|
41.02 millimeters
|
Satisfactory of MR of (US Units)
|
1.664 in
|
Satisfactory of MR of (Metric Units)
|
42.253 millimeters
|
Optional W1 Measurement 1
|
3.2785 in
|
Optional W1 Measurement 2
|
54.5714 sqin
|
DIME Test ID: 2016-01-06-3-2
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 02/01/2016
Date Tested: 01/13/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
55
|
Reading #2
|
54
|
Reading #3
|
55
|
Reading #4
|
56
|
Reading #5
|
55
|
Mean
|
55
|
DIME Test ID: 2016-01-06-3-3
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 02/01/2016
Date Tested: 01/13/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
psi
|
UTM
|
2KIP
|
Humidity
|
50 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.075 in
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2446.8 lbf?in/in?
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.074 in
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2432.4 lbf?in/in?
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.075 in
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2500 lbf?in/in?
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2446.8 psi
|
DIME Test ID: 2016-01-06-3-4
Test Method: ASTM D2628-91-re11-low: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (Low Temp Recovery)
Verified Date: 02/01/2016
Date Tested: 01/15/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Low Temp Recovery (22 hrs at -20F) Size Before (Height of Contact Face )
|
3.5 in
|
Low Temp Recovery (22 hrs at -20F) Size After (Recovered Contact Face )
|
3.297 in
|
Percent Recovery (Low Temp)
|
94 %
|
DIME Test ID: 2016-01-06-3-5
Test Method: ASTM D2628-91-re11-high: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (High Temp Recovery)
Verified Date: 02/01/2016
Date Tested: 01/15/2016
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
High Temp Recovery (70 hrs at 212F) Size Before (Height of Contact Face )
|
3.5 in
|
High Temp Recovery (70 hrs at 212F) Size After (Expanded Contact Face )
|
3.686 in
|
Percent Recovery (High Temp)
|
105 %
|