Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8801 DEA: AML-CEM EFIS: AML-CEM
QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for Cementitious Materials for use in Concrete Authorized Material List (AML)
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2023-07-01-2
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Sample Organization Contact: (916) 227-7071
Type of Sample: Proficiency
Type of Material: Cementitious
Sample Taken Date: 07/01/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/01/2023
The quantity of what the sample constitutes: 1 Bucket
A brief description of the sample: Type I/II Portland Cement
From where was the sample collected: Source
Laboratory sample identification: CM238229
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CCRL Portland Cement 229
DIME Test ID: 2023-07-01-2-1
Test Method: ASTM C187-16: Standard Test Method for Amount of Water Required for Normal Consistency of Hydraulic Cement Paste (Water Normal Consistency)
Verified Date: 08/17/2023
Date Tested: 08/10/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Mass of Water
|
162 g
|
Mass of Dry Cement
|
650 g
|
Water required for normal consistency
|
25.00 %
|
DIME Test ID: 2023-07-01-2-2
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Verified Date: 08/17/2023
Date Tested: 08/10/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Type of Water Used
|
Type IV grade reagent water
|
Initial time of setting
|
130 min
|
Final time of setting
|
205 min
|
DIME Test ID: 2023-07-01-2-3
Test Method: ASTM C266-15: Standard Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore Needles
Verified Date: 08/17/2023
Date Tested: 08/15/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Initial time of setting
|
130 min
|
Final time of setting
|
210 min
|
DIME Test ID: 2023-07-01-2-4
Test Method: ASTM C151-15: Standard Test Method for Autoclave Expansion of Hydraulic Cement
Verified Date: 08/17/2023
Date Tested: 08/15/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Initial length of specimen
|
0.1658
|
Final length of specimen
|
0.1635
|
Change in length of specimen(In percent)
|
-0.02 %
|
Gauge Length
|
10
|
DIME Test ID: 2023-07-01-2-5
Test Method: ASTM C185-15a: Standard Test Method for Air Content of Hydraulic Cement Mortar
Verified Date: 08/17/2023
Date Tested: 08/10/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specific gravity
|
3.108
|
Water Content
|
236
|
The amount of flow (In percent)
|
91 %
|
The amount of water used (In percent)
|
67.43 %
|
Net Weight of Sample
|
830.7 grams
|
Air Content
|
8 %
|
DIME Test ID: 2023-07-01-2-6
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 08/17/2023
Date Tested: 07/20/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
3 days
|
The amount of flow
|
no data %
|
The amount of water used
|
48.5 %
|
Compressive strength of 1st specimen
|
3590 psi
|
Compressive strength of 2nd specimen
|
3575 psi
|
Compressive strength of 3rd specimen
|
3556 psi
|
Average Compressive strength (to nearest 10 psi)
|
3570 psi
|
DIME Test ID: 2023-07-01-2-7
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 08/17/2023
Date Tested: 07/24/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
7 days
|
The amount of flow
|
no data %
|
The amount of water used
|
48.5 %
|
Compressive strength of 1st specimen
|
4592 psi
|
Compressive strength of 2nd specimen
|
4815 psi
|
Compressive strength of 3rd specimen
|
4661 psi
|
Average Compressive strength (to nearest 10 psi)
|
4690 psi
|
DIME Test ID: 2023-07-01-2-8
Test Method: ASTM C109-16a: Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
Verified Date: 08/17/2023
Date Tested: 08/14/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Will control cubes be used per ASTM C311?
|
no
|
Age of specimen
|
28 days
|
The amount of flow
|
no data %
|
The amount of water used
|
48.5 %
|
Compressive strength of 1st specimen
|
6211 psi
|
Compressive strength of 2nd specimen
|
6232 psi
|
Compressive strength of 3rd specimen
|
6101 psi
|
Average Compressive strength (to nearest 10 psi)
|
6180 psi
|
DIME Test ID: 2023-07-01-2-9
Test Method: ASTM C204-11: Standard Test Methods for Fineness of Hydraulic Cement by Air-Permeability Apparatus
Verified Date: 08/17/2023
Date Tested: 08/10/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Method Used
|
Test Method A
|
Test Time
|
106 seconds
|
Fineness
|
4093 cm^2/g
|
DIME Test ID: 2023-07-01-2-10
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Verified Date: 08/17/2023
Date Tested: 08/10/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Corrected residue, % (Rc)
|
13.1 %
|
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325)
|
86.9 %
|
DIME Test ID: 2023-07-01-2-11
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Verified Date: 08/17/2023
Date Tested: 07/31/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Specimen A Initial measurement at 24 hours
|
0.1808 in
|
Specimen B Initial measurement at 24 hours
|
0.2058 in
|
Specimen C Initial measurement at 24 hours
|
0.1694 in
|
Specimen D Initial measurement at 24 hours
|
0.1815 in
|
Specimen A Final measurement at 14 days
|
0.181 in
|
Specimen B Final measurement at 14 days
|
0.2059 in
|
Specimen C Final measurement at 14 days
|
0.1691 in
|
Specimen D Final measurement at 14 days
|
0.1813 in
|
The average length of change of the four specimens
|
-0.001 %
|
DIME Test ID: 2023-07-01-2-12
Test Method: ASTM C451-13: Standard Test Method for Early Stiffening of Hydraulic Cement (Paste Method)
Verified Date: 08/17/2023
Date Tested: 08/15/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Percent final penetration
|
76 %
|
DIME Test ID: 2023-07-01-2-13
Test Method: ASTM C188-15: Standard Test Method for Density of Hydraulic Cement
Verified Date: 08/17/2023
Date Tested: 08/09/2023
Submitted By Organization: CT HQ - Sacramento Cement Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: ben.lenz@dot.ca.gov
Organization Phone: (916) 227-7071
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Density of hydraulic cement
|
3.108 g/cm^3
|