Print Report | Back to Sample Detail

Sample Record for 2023-07-10-41

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215349 DEA: 081C0824 EFIS: 0816000087 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-R104.9/R134.2
Work Description: PLACE HMA (TYPE A), JPCP AND IMPORTED BORROW.
Location Description: RIVERSIDE COUNTY FROM ROUTE 10/177 SEPARATION TO 1.1 MILES WEST OF WILEY'S WELL RD OC
Contractor Name: FISHER SAND & GRAVEL CO.
Contractor Address: 1302 W DRIVERS WAY, TEMPE, AZ. 85284
Resident Engineer: Khoi Vu Structure Rep.: Shukri Abouazra

Sample Information

DIME Sample ID: 2023-07-10-41
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/10/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/12/2023
The quantity of what the sample constitutes: 20 boxes
A brief description of the sample: 3/4" HMA-A-SP-R24 1.0% LSM
From where was the sample collected: Manufacturer
Laboratory sample identification: 0362A-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fisher Sand and Gravel-Tempe

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: CA125MA

Test Results

Test 1 of 8

DIME Test ID: 2023-07-10-41-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 08/01/2023. The corrected test ID is: 2023-07-10-41-5
Reason: corrected

Test 2 of 8

DIME Test ID: 2023-07-10-41-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 08/01/2023. The corrected test ID is: 2023-07-10-41-6
Reason: corrected

Test 3 of 8

DIME Test ID: 2023-07-10-41-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 08/01/2023. The corrected test ID is: 2023-07-10-41-7
Reason: corrected

Test 4 of 8

DIME Test ID: 2023-07-10-41-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 08/01/2023. The corrected test ID is: 2023-07-10-41-8
Reason: corrected

Test 5 of 8

DIME Test ID: 2023-07-10-41-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/01/2023
Date Tested: 07/15/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
The test was superseded from test ID: 2023-07-10-41-1
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2146.9 g
Corrected Asphalt Binder Content 5.11 %
Mass Loss 111.9 g
Correction Factor (Percent by mass of HMA Specimen) -0.04 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 538 C

Test 6 of 8

DIME Test ID: 2023-07-10-41-6
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/01/2023
Date Tested: 07/15/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
The test was superseded from test ID: 2023-07-10-41-2
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests 1
What is the unit of measurement for theoretical density? SI Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 7352.6 grams
Mass of oven-dry sample in air for Sample 1 2557.0 grams
Mass of container filled with the sample and water for Sample 1 8883.7 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.492
Theoretical maximum density at 25°C (77°F) 2484.8 kg/m^3

Test 7 of 8

DIME Test ID: 2023-07-10-41-7
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/01/2023
Date Tested: 07/15/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
The test was superseded from test ID: 2023-07-10-41-3
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.0 %
Percent Air Voids 2 3.0 %
Percent Air Voids 3 3.0 %
Percent Air Voids Average 3.0 %

Test 8 of 8

DIME Test ID: 2023-07-10-41-8
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/01/2023
Date Tested: 07/15/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
The test was superseded from test ID: 2023-07-10-41-4
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity 2.417
Bulk Specific Gravity 2 2.416
Bulk Specific Gravity 3 2.417
Average Bulk Specific Gravity 2.417