Sample Record for 2023-07-10-41
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 215349 DEA: 081C0824 EFIS: 0816000087
QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-10-R104.9/R134.2
Work Description: PLACE HMA (TYPE A), JPCP AND IMPORTED BORROW.
Location Description: RIVERSIDE COUNTY FROM ROUTE 10/177 SEPARATION TO 1.1 MILES WEST OF WILEY'S WELL RD OC
Contractor Name: FISHER SAND & GRAVEL CO.
Contractor Address: 1302 W DRIVERS WAY, TEMPE, AZ. 85284
Resident Engineer: Khoi Vu Structure Rep.: Shukri Abouazra
Sample Information
DIME Sample ID: 2023-07-10-41
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Production Start-Up
Type of Material: Hot Mix Asphalt
Sample Taken Date: 07/10/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/12/2023
The quantity of what the sample constitutes: 20 boxes
A brief description of the sample: 3/4" HMA-A-SP-R24 1.0% LSM
From where was the sample collected: Manufacturer
Laboratory sample identification: 0362A-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Fisher Sand and Gravel-Tempe
Material Information
HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: CA125MA
Test Results
Test 1 of 8
DIME Test ID: 2023-07-10-41-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 08/01/2023. The corrected test ID is: 2023-07-10-41-5
Reason: corrected
Test 2 of 8
DIME Test ID: 2023-07-10-41-2
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 08/01/2023. The corrected test ID is: 2023-07-10-41-6
Reason: corrected
Test 3 of 8
DIME Test ID: 2023-07-10-41-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 08/01/2023. The corrected test ID is: 2023-07-10-41-7
Reason: corrected
Test 4 of 8
DIME Test ID: 2023-07-10-41-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
This test has been superseded on 08/01/2023. The corrected test ID is: 2023-07-10-41-8
Reason: corrected
Test 5 of 8
DIME Test ID: 2023-07-10-41-5
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 08/01/2023
Date Tested: 07/15/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
The test was superseded from test ID: 2023-07-10-41-1
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used?
|
Celsius
|
Test procedure used?
|
Method A
|
Mass of HMA Sample prior to ignition
|
2146.9 g
|
Corrected Asphalt Binder Content
|
5.11 %
|
Mass Loss
|
111.9 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
-0.04 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.00 %
|
Test Temperature
|
538 C
|
Test 6 of 8
DIME Test ID: 2023-07-10-41-6
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 08/01/2023
Date Tested: 07/15/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
The test was superseded from test ID: 2023-07-10-41-2
Test Result Compliance: not applicable
Additional Comments When Verified:
Number of tests
|
1
|
What is the unit of measurement for theoretical density?
|
SI Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water
|
7352.6 grams
|
Mass of oven-dry sample in air for Sample 1
|
2557.0 grams
|
Mass of container filled with the sample and water for Sample 1
|
8883.7 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.492
|
Theoretical maximum density at 25°C (77°F)
|
2484.8 kg/m^3
|
Test 7 of 8
DIME Test ID: 2023-07-10-41-7
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 08/01/2023
Date Tested: 07/15/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
The test was superseded from test ID: 2023-07-10-41-3
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids
|
3.0 %
|
Percent Air Voids 2
|
3.0 %
|
Percent Air Voids 3
|
3.0 %
|
Percent Air Voids Average
|
3.0 %
|
Test 8 of 8
DIME Test ID: 2023-07-10-41-8
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 08/01/2023
Date Tested: 07/15/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
The test was superseded from test ID: 2023-07-10-41-4
Test Result Compliance: not applicable
Additional Comments When Verified:
Bulk Specific Gravity
|
2.417
|
Bulk Specific Gravity 2
|
2.416
|
Bulk Specific Gravity 3
|
2.417
|
Average Bulk Specific Gravity
|
2.417
|