Print Report | Back to Sample Detail

Sample Record for 2023-07-13-4

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214469 DEA: 030H08U4 EFIS: 0319000029 QA Service Level: 1
DIST-CO-RTE-PM: 03-SAC-50-L0.2/R6.1
Work Description: Sac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location Description: FROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
Contractor Name: FLATIRON WEST INC
Contractor Address: 2100 Goodyear Rd., Benicia, CA 94510
Resident Engineer: Jim Rogers Structure Rep.: Daniel Eggers

Sample Information

DIME Sample ID: 2023-07-13-4
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Bay Area Field Office
Sample Organization Contact: (916) 284-6784
Type of Sample: Verification
Type of Material: SMTL TM5 - Headed Bars
Sample Taken Date: 07/13/2023
Date that the sample was received by the laboratory/organization performing the testing: 07/14/2023
The quantity of what the sample constitutes: 32 TTMGT with Doughnut bars
A brief description of the sample: ASTM A706, GR 60 Headed bar
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name: US-50
The fabricator/manufacturer/facility name: Martinez Steel Fresno

Material Information

Production or Authorization Testing: Production Testing
Rebar Heat Number(s): 435622
Head Manufacturer Lot Number(s): A211864 4000005119 8U1/B1
Rebar Size: #14
Headed Bar Model Name: Taper Threaded Grip Twist male with doughnut
Size of Head: Full Size - 9x
Head Connection Type: Taper Threaded
Head Shape: Circular
Rebar Manufacturer: Cascade Steel
Head Manufacturer: Bar Splice Products
Head Fabricator: Bar Splice Products
Material Standard Code: ASTM A706
Headed Bar Unique ID: 9TH-17-01

Test Results

Test 1 of 3

DIME Test ID: 2023-07-13-4-1
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/18/2023
Date Tested: 07/17/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
12.25226899100844Ok Neckingaauvinen
Temperature 72 f
UTM 400kip

Test 2 of 3

DIME Test ID: 2023-07-13-4-2
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/18/2023
Date Tested: 07/17/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
12.25227432101081Ok Neckingaauvinen
Temperature 72 f
UTM 400kip

Test 3 of 3

DIME Test ID: 2023-07-13-4-3
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Verified Date: 07/18/2023
Date Tested: 07/17/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: Ok Necking
Test Result Compliance:
Additional Comments When Verified:
Number of Headed Bar Samples 1
Lot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
12.25227843101264Ok Neckingaauvinen
Temperature 72 f
UTM 400kip