Print Report | Back to Sample Detail

Sample Record for 2015-12-11-25

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 8196 DEA: 59912684 QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2015-12-11-25
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 12/11/2015
Date that the sample was received by the laboratory/organization performing the testing: 12/22/2015
The quantity of what the sample constitutes: 3
A brief description of the sample: .6in Prestressing Strand
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden

Material Information

Comments: Unknown
Reel/Coil/Pack Number(s): S333508-3, S377272-1
Number of Coils: Unknown
Group Number: 10832
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0544415-2
Mfg. Lot Number(s): 10832
Manufacturer(s): Sumiden

Test Results

Test 1 of 2

DIME Test ID: 2015-12-11-25-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 01/05/2016
Date Tested: 12/30/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 2
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
S0544415-2S333508-30.218602975494627.81.72DAVE
S0544415-2S377272-10.2186077627.91.74DAVE
UTM 120KIP
Temperature 70 F
Extensometers E88766

Test 2 of 2

DIME Test ID: 2015-12-11-25-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 01/05/2016
Date Tested: 12/30/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 2
Dia of the Center Wire (in)Dia of the Outer Wire 1 (in)Dia of the Outer Wire 2 (in)Dia of the Outer Wire 3 (in)Dia of the Outer Wire 4 (in)Dia of the Outer Wire 5 (in)Dia of the Outer Wire 6 (in)Area (sqin)
0.2070.1980.1980.1980.1970.1980.1980.218
0.2070.1980.1980.1980.1980.1970.1970.218