Sample Record for 2023-06-02-63
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 993184 DEA: 040A7724 EFIS: 0420000288 COOP: 042763
QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-80-6.4/6.8
Work Description: Excavation, HMA, structural concrete, minor concrete and drainage.
Location Description: IN BERKELEY AND ALBANY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.3 MILE SOUTH OF EL CERRITO SEPARATION AND OVERHEAD
Contractor Name: OC Jones (Will Dieterich)
Contractor Address: 1520 Fourth Street, Berkeley, CA 94710
Resident Engineer: Maxime Dabilly Structure Rep.: Eric Urementa
Sample Information
DIME Sample ID: 2023-06-02-63
TL Number from the TL Form:
Sample Submitted By Organization: Golden State Bridge, Incorporated
Sample Organization Contact: (415) 720-6577
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/02/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/02/2023
The quantity of what the sample constitutes: 5 cylindrical samples
A brief description of the sample: 7' of column lower section concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Central Concrete Supply
Material Information
The concrete mix design number: 4E0CG5E1
The truck number from where the sample was collected: 6302
The batch plant ticket number from where the sample was collected: 354713
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Stair 4 - Columns at bent 1,2 and 3 on the west side
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 1
DIME Test ID: 2023-06-02-63-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/14/2023
Date Tested: 06/09/2023
Submitted By Organization: Golden State Bridge, Incorporated
Organization Address: 3701 Mallard Drive ,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: paul@gsbridge.com
Organization Phone: (415) 720-6577
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
5
|
Test performed
|
With no density determined
|
Apparent mass of submerged cylinder 1
|
8 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Average diameter of cylinder 4
|
4.00 in
|
Average diameter of cylinder 5
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Cross sectional area of cylinder 4
|
12.57 in^2
|
Cross sectional area of cylinder 5
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
4220 psi
|
Maximum load on cylinder 1
|
53060 lb
|
Maximum load on cylinder 2
|
0 lb
|
Maximum load on cylinder 3
|
0 lb
|
Maximum load on cylinder 4
|
0 lb
|
Maximum load on cylinder 5
|
0 lb
|
Type of fracture pattern of cylinder 1
|
1
|
Type of fracture pattern of cylinder 2
|
1
|
Type of fracture pattern of cylinder 3
|
1
|
Type of fracture pattern of cylinder 4
|
1
|
Type of fracture pattern of cylinder 5
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Correction factor for cylinder 2
|
1.00
|
Correction factor for cylinder 3
|
1.00
|
Correction factor for cylinder 4
|
1.00
|
Correction factor for cylinder 5
|
1.00
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
0 hours
|
Serial number of delivery ticket, if available
|
no data
|