Print Report | Back to Sample Detail

Sample Record for 2023-05-17-111

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993184 DEA: 040A7724 EFIS: 0420000288 COOP: 042763 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-80-6.4/6.8
Work Description: Excavation, HMA, structural concrete, minor concrete and drainage.
Location Description: IN BERKELEY AND ALBANY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.3 MILE SOUTH OF EL CERRITO SEPARATION AND OVERHEAD
Contractor Name: OC Jones (Will Dieterich)
Contractor Address: 1520 Fourth Street, Berkeley, CA 94710
Resident Engineer: Maxime Dabilly Structure Rep.: Eric Urementa

Sample Information

DIME Sample ID: 2023-05-17-111
TL Number from the TL Form:
Sample Submitted By Organization: Golden State Bridge, Incorporated
Sample Organization Contact: (415) 720-6577
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 05/17/2023
Date that the sample was received by the laboratory/organization performing the testing: 05/19/2023
The quantity of what the sample constitutes: 5 samples
A brief description of the sample: CIDH pile concrete sample
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Right Away Ready Mix

Material Information

The concrete mix design number: DDJ118E3
The truck number from where the sample was collected: 6191
The batch plant ticket number from where the sample was collected: 03445232
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Bent 2 - CIDH Pile - Stair at span 4 on the west side
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-05-17-111-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 08/14/2023
Date Tested: 06/16/2023
Submitted By Organization: Golden State Bridge, Incorporated
Organization Address: 3701 Mallard Drive ,
Organization City: Benicia
Organization State: CA
Organization Zipcode: 94510
Organization Email: paul@gsbridge.com
Organization Phone: (415) 720-6577
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 5
Test performed With no density determined
Apparent mass of submerged cylinder 1 8 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Average diameter of cylinder 4 4.00 in
Average diameter of cylinder 5 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Cross sectional area of cylinder 4 12.57 in^2
Cross sectional area of cylinder 5 12.57 in^2
Compressive strength (to nearest 10 psi) 8230 psi
Maximum load on cylinder 1 80720 lb
Maximum load on cylinder 2 100180 lb
Maximum load on cylinder 3 105040 lb
Maximum load on cylinder 4 105110 lb
Maximum load on cylinder 5 0 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 3
Type of fracture pattern of cylinder 4 3
Type of fracture pattern of cylinder 5 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Correction factor for cylinder 3 1.00
Correction factor for cylinder 4 1.00
Correction factor for cylinder 5 1.00
Age of specimen 28 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data