Print Report | Back to Sample Detail

Sample Record for 2023-06-26-66

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215666 DEA: 11430564 EFIS: 1119000015 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-67-R6.0/24.4
Work Description: COLD PLANE, RHMA OVERLAY AND HFST, AND INSTALL CHANNELIZERS.
Location Description: SAN DIEGO COUNTY NEAR LAKESIDE AND RAMONA FROM 0.2 MILE NORTH OF SAN DIEGO RIVER BRIDGE TO ROUTE 78
Contractor Name: ATP General Engineering
Contractor Address: 4211 Ponderosa Ave, Suite C, San Diego, CA 92123
Resident Engineer: Victor Mercado Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-06-26-66
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 688-1570
Type of Sample: Quality Assurance
Type of Material: Aggregate
Sample Taken Date: 06/26/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/26/2023
The quantity of what the sample constitutes: 12 boxes 2 bags
A brief description of the sample: 3/4" RHMA-G
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-37-0036
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Plant
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 1

DIME Test ID: 2023-06-26-66-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 10/27/2023
Date Tested: 07/14/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 98 %
Cumulative percent passing the 1/2 in. sieve 85 %
Cumulative percent passing the 3/8 in. sieve 65 %
Cumulative percent passing the #4 sieve 40 %
Cumulative percent passing the #8 sieve 33 %
Cumulative percent passing the #16 sieve 21 %
Cumulative percent passing the #30 sieve 7 %
Cumulative percent passing the #50 sieve 3 %
Cumulative percent passing the #100 sieve 2 %
Cumulative percent passing the #200 sieve 0.1 %

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-06-26-66-2AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)07/10/202307/14/2023Melchor OronozCT D11 - District 11 Materials LaboratoryMelchor Oronoz
2023-06-26-66-3ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)07/10/202307/14/2023Melchor OronozCT D11 - District 11 Materials LaboratoryMelchor Oronoz
2023-06-26-66-4AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)07/10/202307/14/2023Melchor OronozCT D11 - District 11 Materials LaboratoryMelchor Oronoz
2023-06-26-66-5CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)07/10/202307/14/2023Melchor OronozCT D11 - District 11 Materials LaboratoryMelchor Oronoz
2023-06-26-66-6AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)07/10/202307/14/2023Melchor OronozCT D11 - District 11 Materials LaboratoryMelchor Oronoz
2023-06-26-66-7AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)07/10/202307/14/2023Melchor OronozCT D11 - District 11 Materials LaboratoryMelchor Oronoz
2023-06-26-66-8AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)07/10/202307/14/2023Melchor OronozCT D11 - District 11 Materials LaboratoryMelchor Oronoz
2023-06-26-66-9AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)07/10/202307/14/2023Melchor OronozCT D11 - District 11 Materials LaboratoryMelchor Oronoz
2023-06-26-66-10AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)07/10/202307/14/2023Melchor OronozCT D11 - District 11 Materials LaboratoryRAPMelchor Oronoz
2023-06-26-66-11AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)07/10/202307/14/2023Melchor OronozCT D11 - District 11 Materials LaboratoryRAPMelchor Oronoz