Sample Record for 2023-06-26-65

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215666 DEA: 11430564 EFIS: 1119000015 QA Service Level: 1
DIST-CO-RTE-PM: 11-SD-67-R6.0/24.4
Work Description: COLD PLANE, RHMA OVERLAY AND HFST, AND INSTALL CHANNELIZERS.
Location Description: SAN DIEGO COUNTY NEAR LAKESIDE AND RAMONA FROM 0.2 MILE NORTH OF SAN DIEGO RIVER BRIDGE TO ROUTE 78
Contractor Name: ATP General Engineering
Contractor Address: 4211 Ponderosa Ave, Suite C, San Diego, CA 92123
Resident Engineer: Victor Mercado Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-06-26-65
TL Number from the TL Form:
Sample Submitted By Organization: CT D11 - District 11 Materials Laboratory
Sample Organization Contact: (858) 688-1570
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 06/26/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/26/2023
The quantity of what the sample constitutes: 12 boxes 3 bags
A brief description of the sample: 3/4" HMA-A
From where was the sample collected: Supplier
Laboratory sample identification: 7209-JMF
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta Lakeside

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number:
Sublot number:
HMA Mix Number: 23417005SR

Test Results

Test 1 of 7

DIME Test ID: 2023-06-26-65-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/21/2023
Date Tested: 07/14/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of the specimen basket assembly 4006.7 g
Mass of the specimen and specimen basket assembly prior to ignition 5909.7 g
Mass of HMA Sample prior to ignition 1903.0 g
Corrected Asphalt Binder Content 4.74 %
Mass Loss 99.6 g
Mass of aggregate remaining after ignition 1803.4 g
Correction Factor (Percent by mass of HMA Specimen) 0.49 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 538 F

Test 2 of 7

DIME Test ID: 2023-06-26-65-2
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 07/21/2023
Date Tested: 07/14/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 1
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Method Performed Mechanical Agitation - Method A
Mass of container filled with water 1 7477.1 grams
Mass of oven-dry sample in air for Sample 1 2575.9 grams
Mass of container filled with the sample and water for Sample 1 9018.9 grams
Temperature of Water 77 °F
Specific Gravity for Sample 1 2.491
Theoretical maximum density at 25°C (77°F) 155.1 lb/ft^3

Test 3 of 7

DIME Test ID: 2023-06-26-65-3
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Verified Date: 07/21/2023
Date Tested: 07/14/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent Air Voids 3.8 %
Percent Air Voids 2 3.9 %
Percent Air Voids 3 3.5 %
Percent Air Voids Average 3.7 %

Test 4 of 7

DIME Test ID: 2023-06-26-65-4
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 07/21/2023
Date Tested: 07/14/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity 2.396
Bulk Specific Gravity 2 2.395
Bulk Specific Gravity 3 2.403
Average Bulk Specific Gravity 2.398

Test 5 of 7

DIME Test ID: 2023-06-26-65-5
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Verified Date: 07/21/2023
Date Tested: 07/19/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? SI Units
Average Dry Tensile Strength 200 psi
Average Wet Tensile Strength 95 psi
Tensile Strength Ratio 0.48

Test 6 of 7

DIME Test ID: 2023-06-26-65-6
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Verified Date: 07/21/2023
Date Tested: 07/19/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Test Temperature 113 F
Type and Amount of Anti-Stripping Additive 1.0%
Stripping Inflection Point (Wheel A) >10000
Stripping Inflection Point (Wheel B) >10000
Maximum impression at 5000 passes (left wheel) 0.76 mm
Maximum impression at 5000 passes (right wheel) 1.32 mm
Average impression at 5000 passes (left/right avg) 1.04 mm
Maximum impression at 10000 passes (left wheel) 0.83 mm
Maximum impression at 10000 passes (right wheel) 1.58 mm
Average impression at 10000 passes (left/right avg) 1.21 mm
Average impression at 15000 passes (left/right avg) no data
Average impression at 20000 passes (left/right avg) no data
Average impression at 25000 passes (left/right avg) no data

Test 7 of 7

DIME Test ID: 2023-06-26-65-7
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 07/21/2023
Date Tested: 07/14/2023
Submitted By Organization: CT D11 - District 11 Materials Laboratory
Organization Address: 7177 Opportunity Road,
Organization City: San Diego
Organization State: CA
Organization Zipcode: 92111
Organization Email: dave.m.cortez@dot.ca.gov
Organization Phone: (858) 688-1570
General Comments for this Test: RAP
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Fahrenheit
Test procedure used? Method A
Mass of the specimen basket assembly 4016.7 g
Mass of the specimen and specimen basket assembly prior to ignition 5578.4 g
Mass of HMA Sample prior to ignition 1561.7 g
Corrected Asphalt Binder Content 6.98 %
Mass Loss 109.0 g
Mass of aggregate remaining after ignition 1452.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.00 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 538 F