Project ID: 994408 DEA: 051K03U4 EFIS: 0522000026
QA Service Level: 1
DIST-CO-RTE-PM: 05-SLO-101-
Work Description: !!PLEASE CC Office Engineer Barbara Riccardi on reports to RE and SR!! Construct 2 roundabouts in Montecito along US 101.
Location Description:
Contractor Name: Veronica Mchugh
Contractor Address: 5335 DEBBIE ROAD, SANTA BARBARA, CA 93111
Resident Engineer: Taylor Merlo Structure Rep.: Josh Madrigal
DIME Sample ID: 2023-06-03-10
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Sample Organization Contact: (805) 621-3616
Type of Sample: Department Acceptance
Type of Material: Concrete
Sample Taken Date: 06/03/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/13/2023
The quantity of what the sample constitutes: 30cy
A brief description of the sample: Concrete beams
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CEMEX Santa Barbara
The concrete mix design number: 1625995
The truck number from where the sample was collected: 10067296
The batch plant ticket number from where the sample was collected: 30769034
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-06-03-10-1
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Verified Date: 06/30/2023
Date Tested: 06/13/2023
Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Organization Address: 21 Griffin Road North,
Organization City: Windsor
Organization State: CT
Organization Zipcode: 06095-1590
Organization Email: dlachaine@trccompanies.com
Organization Phone: (805) 621-3616
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens
|
2
|
Unit system used?
|
US Units
|
Does the testing machine measure load or stress on the beam specimen?
|
Load
|
Fracture initiates in the tension surface
|
Within the Middle Third of the Span Length
|
Is a beam dimensional correction factor used?
|
Yes
|
Modulus of rupture average
|
630 psi
|
Modulus of rupture
|
670 psi
|
Modulus of rupture 2
|
590 psi
|
Age of specimen
|
9 days
|