Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993848 DEA: 081N0704 EFIS: 0822000087
QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-40-R140.8/R148.5
Work Description: GRAVEL MULCH, ROCK BLANKET, AND IMPORTED BORROW
Location Description: SAN BERNARDINO COUNTY IN NEEDLES AT VARIOUS LOCATIONS FROM NEEDLES HIGHWAY TO FIVE MILE ROAD
Contractor Name: Griffith Company
Contractor Address: 3050 E. Birch Street, Brea, California 92821
Resident Engineer: Dave Benson Structure Rep.: jegbefume adodo
DIME Sample ID: 2023-06-23-24
TL Number from the TL Form:
Sample Submitted By Organization: Universal Precast Concrete - Redding
Sample Organization Contact: (530) 243-6477
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/23/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/22/2023
The quantity of what the sample constitutes: 3CY
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Precast Unlimited
The concrete mix design number: 5
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 1
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Batch Plant Loader Bucket
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-06-23-24-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 06/26/2023
Date Tested: 06/23/2023
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Road,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: mikeb@universalprecast.com
Organization Phone: (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2023-06-23-24-2
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 06/26/2023
Date Tested: 06/23/2023
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Road,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: mikeb@universalprecast.com
Organization Phone: (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample
|
GR0623
|
Volume of the measure
|
0.248 ft^3
|
Density of concrete
|
148 lb/ft^3
|
Yield of concrete
|
no data
|
Relative yield of the batch
|
no data
|
Cement content
|
no data
|
Air content
|
no data
|
DIME Test ID: 2023-06-23-24-3
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 06/26/2023
Date Tested: 06/23/2023
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Road,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: mikeb@universalprecast.com
Organization Phone: (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2023-06-23-24-4
Test Method: ASTM C231-17a: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method
Verified Date: 06/26/2023
Date Tested: 06/23/2023
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Road,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: mikeb@universalprecast.com
Organization Phone: (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
DIME Test ID: 2023-06-23-24-5
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/26/2023
Date Tested: 06/26/2023
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Road,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: mikeb@universalprecast.com
Organization Phone: (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
1
|
Test performed
|
With no density determined
|
Apparent mass of submerged cylinder 1
|
8.5 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Compressive strength of cylinder (to nearest 10 psi)
|
3400 psi
|
Maximum load on cylinder 1
|
42740 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Age of specimen
|
3 days
|
Age of specimen in hours
|
0 hours
|
Serial number of delivery ticket, if available
|
no data
|
DIME Test ID: 2023-06-23-24-6
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/30/2023
Date Tested: 06/30/2023
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Road,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: mikeb@universalprecast.com
Organization Phone: (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Apparent mass of submerged cylinder 1
|
8.5 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
4310 psi
|
Maximum load on cylinder 1
|
55250 lb
|
Maximum load on cylinder 2
|
53110 lb
|
Type of fracture pattern of cylinder 1
|
3
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Correction factor for cylinder 2
|
1.00
|
Age of specimen
|
7 days
|
Age of specimen in hours
|
0 hours
|
Serial number of delivery ticket, if available
|
no data
|
DIME Test ID: 2023-06-23-24-7
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/21/2023
Date Tested: 07/21/2023
Submitted By Organization: Universal Precast Concrete - Redding
Organization Address: 16538 Clear Creek Road,
Organization City: Redding
Organization State: CA
Organization Zipcode: 96001
Organization Email: mikeb@universalprecast.com
Organization Phone: (530) 243-6477
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Apparent mass of submerged cylinder 1
|
8.5 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
5810 psi
|
Maximum load on cylinder 1
|
72400 lb
|
Maximum load on cylinder 2
|
73660 lb
|
Type of fracture pattern of cylinder 1
|
4
|
Type of fracture pattern of cylinder 2
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Correction factor for cylinder 2
|
1.00
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
0 hours
|
Serial number of delivery ticket, if available
|
no data
|