Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2015-11-24-14
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 11/24/2015
Date that the sample was received by the laboratory/organization performing the testing: 11/24/2015
The quantity of what the sample constitutes: 8
A brief description of the sample: strand
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden
Comments: Unknown
Reel/Coil/Pack Number(s): S3773013 S3773023 S3773031 S3773106 S3773113 S3773135 S3773162 S3773163
Number of Coils: Unknown
Group Number: 10813
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0278887 S0277712 S0278888 S0277717 S0587515
Mfg. Lot Number(s): NA
Manufacturer(s): EVRAZ Cascade
DIME Test ID: 2015-11-24-14-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 12/18/2015
Date Tested: 12/03/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
8
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | SO278887 | S377301-3 | 0.218 | 59636 | 55275 | 27.9 | 1.76 | DAVE | SO278887 | S377302-3 | 0.217 | 59559 | | 28.1 | 1.73 | DAVE | SO277712 | S377303-1 | 0.217 | 59589 | | 29.2 | 1.86 | DAVE | SO278888 | S377310-6 | 0.217 | 61004 | | 28.4 | 1.68 | DAVE | SO277717 | S377311-3 | 0.217 | 58717 | | 27.7 | 1.58 | DAVE | SO277717 | S377313-5 | 0.217 | 59278 | | 28 | 1.69 | DAVE | SO587515 | S377316-2 | 0.217 | 59094 | | 28 | 1.71 | DAVE | SO587515 | S377316-3 | 0.217 | 59261 | | 27.9 | 1.73 | DAVE |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88766
|
DIME Test ID: 2015-11-24-14-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 12/18/2015
Date Tested: 12/03/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
8
|
Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) | .207 | .198 | .198 | .197 | .198 | .198 | .197 | 0.218 | .207 | .197 | .197 | .197 | .197 | .198 | .197 | 0.217 | .207 | .197 | .197 | .197 | .198 | .198 | .197 | 0.217 | .208 | .198 | .197 | .197 | .197 | .197 | .198 | 0.217 | .208 | .198 | .197 | .197 | .197 | .197 | .197 | 0.217 | .207 | .197 | .197 | .197 | .197 | .197 | .197 | 0.217 | .207 | .197 | .198 | .197 | .197 | .197 | .197 | 0.217 | .207 | .198 | .197 | .197 | .197 | .197 | .197 | 0.217 |
| |