Print Report | Back to Sample Detail

Sample Record for 2015-11-24-14

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 8196 DEA: 59912684 QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2015-11-24-14
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 11/24/2015
Date that the sample was received by the laboratory/organization performing the testing: 11/24/2015
The quantity of what the sample constitutes: 8
A brief description of the sample: strand
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Sumiden

Material Information

Comments: Unknown
Reel/Coil/Pack Number(s): S3773013 S3773023 S3773031 S3773106 S3773113 S3773135 S3773162 S3773163
Number of Coils: Unknown
Group Number: 10813
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): S0278887 S0277712 S0278888 S0277717 S0587515
Mfg. Lot Number(s): NA
Manufacturer(s): EVRAZ Cascade

Test Results

Test 1 of 2

DIME Test ID: 2015-11-24-14-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 12/18/2015
Date Tested: 12/03/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 8
Heat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
SO278887S377301-30.218596365527527.91.76DAVE
SO278887S377302-30.2175955928.11.73DAVE
SO277712S377303-10.2175958929.21.86DAVE
SO278888S377310-60.2176100428.41.68DAVE
SO277717S377311-30.2175871727.71.58DAVE
SO277717S377313-50.21759278281.69DAVE
SO587515S377316-20.21759094281.71DAVE
SO587515S377316-30.2175926127.91.73DAVE
UTM 120KIP
Temperature 70 F
Extensometers E88766

Test 2 of 2

DIME Test ID: 2015-11-24-14-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 12/18/2015
Date Tested: 12/03/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples 8
Dia of the Center Wire (in)Dia of the Outer Wire 1 (in)Dia of the Outer Wire 2 (in)Dia of the Outer Wire 3 (in)Dia of the Outer Wire 4 (in)Dia of the Outer Wire 5 (in)Dia of the Outer Wire 6 (in)Area (sqin)
.207.198.198.197.198.198.1970.218
.207.197.197.197.197.198.1970.217
.207.197.197.197.198.198.1970.217
.208.198.197.197.197.197.1980.217
.208.198.197.197.197.197.1970.217
.207.197.197.197.197.197.1970.217
.207.197.198.197.197.197.1970.217
.207.198.197.197.197.197.1970.217