Sample Record for 2023-06-14-73
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994244 DEA: 051F6204 EFIS: 0514000039
QA Service Level: 1
DIST-CO-RTE-PM: 05-SCR-152-1.9
Work Description: WIDEN BRIDGE, CONCRETE BARRIER, AND MODIFY ELECTRICAL SYSTEM.
Location Description: SANTA CRUZ COUNTY NEAR WATSONVILLE AT CORRALITOS CREEK BRIDGE
Contractor Name: Bridgeway Civil Constructors, Inc
Contractor Address: 3333 Vaca Valley Parkway, Suite 2000, Vacaville, CA 95688
Resident Engineer: David Hopper Structure Rep.: David Galarza
Sample Information
DIME Sample ID: 2023-06-14-73
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Sample Organization Contact: 831-818-0254
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 06/14/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/22/2023
The quantity of what the sample constitutes: 45 CY
A brief description of the sample: PCC
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 36-0001
Structure name: Corralitos Creek Bridge
The fabricator/manufacturer/facility name: Graniterock
Material Information
The concrete mix design number: 572590
The truck number from where the sample was collected: 2424
The batch plant ticket number from where the sample was collected: 421062
Concrete batch plant: Graniterock
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled: Barrier rail
From Lot No.:
Bag Lot No.:
Test Results
Test 1 of 3
DIME Test ID: 2023-06-14-73-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 07/17/2023
Date Tested: 07/12/2023
Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Organization Address: 1529 Salinas Highway,
Organization City: Monterey
Organization State: CA
Organization Zipcode: 93940
Organization Email: wesley.rider@dot.ca.gov
Organization Phone: (831) 818-0254
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Average diameter of cylinder 1
|
4.03 in
|
Average diameter of cylinder 2
|
4.03 in
|
Average diameter of cylinder 3
|
4.03 in
|
Cross sectional area of cylinder 1
|
12.76 in^2
|
Cross sectional area of cylinder 2
|
12.76 in^2
|
Cross sectional area of cylinder 3
|
12.76 in^2
|
Compressive strength (to nearest 10 psi)
|
4960 psi
|
Maximum load on cylinder 1
|
64000 lb
|
Maximum load on cylinder 2
|
66760 lb
|
Maximum load on cylinder 3
|
58900 lb
|
Type of fracture pattern of cylinder 1
|
1
|
Type of fracture pattern of cylinder 2
|
1
|
Type of fracture pattern of cylinder 3
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Correction factor for cylinder 2
|
1.00
|
Correction factor for cylinder 3
|
1.00
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
no data0 hours
|
Test 2 of 3
DIME Test ID: 2023-06-14-73-2
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 06/28/2023
Date Tested: 06/14/2023
Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Organization Address: 1529 Salinas Highway,
Organization City: Monterey
Organization State: CA
Organization Zipcode: 93940
Organization Email: wesley.rider@dot.ca.gov
Organization Phone: (831) 818-0254
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Test 3 of 3
DIME Test ID: 2023-06-14-73-3
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 06/28/2023
Date Tested: 06/14/2023
Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Organization Address: 1529 Salinas Highway,
Organization City: Monterey
Organization State: CA
Organization Zipcode: 93940
Organization Email: wesley.rider@dot.ca.gov
Organization Phone: (831) 818-0254
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: