Print Report | Back to Sample Detail

Sample Record for 2023-06-13-41

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994441 DEA: 081A8304 EFIS: 0800000579 COOP: 081746 QA Service Level: 2
DIST-CO-RTE-PM: 08---
Work Description: Widening the existing Cedar Avenue overcrossing (OC) from 6 to 10 lanes, replacing the Union Pacific Railroad overhead (OH), widening Cedar Avenue from 4 to 6 through lanes, and realigning and/or widening the interchange entrance and exit ramps
Location Description: At the Interstate 10 (I-10) Cedar Avenue Interchange from PM 17.8 to 19.3 in the County of San Bernardino (County)
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Kee Ooi Structure Rep.: Matt Bruce

Sample Information

DIME Sample ID: 2023-06-13-41
TL Number from the TL Form:
Sample Submitted By Organization: Con-Fab California Corporation - Lathrop
Sample Organization Contact: (209) 249-4700
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 06/13/2023
Date that the sample was received by the laboratory/organization performing the testing: 06/14/2023
The quantity of what the sample constitutes: 1 CF of Concrete for Testing
A brief description of the sample: Bed 1B, 4th Truck
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Con-Fab California, LLC

Material Information

The concrete mix design number: VER-98LV
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 8729
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Bed 1B, 4th Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 6

DIME Test ID: 2023-06-13-41-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 06/16/2023
Date Tested: 06/14/2023
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? no data
Apparent mass of submerged cylinder 1 8.94 lb
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.56 in^2
Cross sectional area of cylinder 2 12.56 in^2
Cross sectional area of cylinder 3 12.56 in^2
Compressive strength (to nearest 10 psi) 7470 psi
Maximum load on cylinder 1 94510 lb
Maximum load on cylinder 2 93305 lb
Maximum load on cylinder 3 93585 lb
Type of fracture pattern of cylinder 1 4
Type of fracture pattern of cylinder 2 4
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1.00
Correction factor for cylinder 2 1.00
Correction factor for cylinder 3 1.00
Age of specimen 1 days
Age of specimen in hours 0 hours
Serial number of delivery ticket, if available no data

Test 2 of 6

DIME Test ID: 2023-06-13-41-2
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 East Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email:
Organization Phone: (209) 249-4700
This test has been superseded on 06/19/2023. The corrected test ID is: 2023-06-13-41-4
Reason: retested

Test 3 of 6

DIME Test ID: 2023-06-13-41-3
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 East Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email:
Organization Phone: (209) 249-4700
This test has been superseded on 06/19/2023. The corrected test ID is: 2023-06-13-41-5
Reason: corrected

Test 4 of 6

DIME Test ID: 2023-06-13-41-4
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 East Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email:
Organization Phone: (209) 249-4700
This test has been superseded on 06/19/2023. The corrected test ID is: 2023-06-13-41-6
Reason: retested

Test 5 of 6

DIME Test ID: 2023-06-13-41-5
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 06/19/2023
Date Tested: 06/13/2023
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test:
The test was superseded from test ID: 2023-06-13-41-3
Test Result Compliance:
Additional Comments When Verified:
Temperature 71 F

Test 6 of 6

DIME Test ID: 2023-06-13-41-6
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 06/19/2023
Date Tested: 06/13/2023
Submitted By Organization: Con-Fab California Corporation - Lathrop
Organization Address: 1910 Lathrop Road,
Organization City: Lathrop
Organization State: CA
Organization Zipcode: 95330
Organization Email: dannyc@confabca.com
Organization Phone: (209) 249-4717
General Comments for this Test: Spread
The test was superseded from test ID: 2023-06-13-41-4
Test Result Compliance:
Additional Comments When Verified:
Slump 21 inch