Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 8196 DEA: 59912684
QA Service Level: 1
DIST-CO-RTE-PM: 59---
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown
DIME Sample ID: 2015-11-10-10
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM4 - Prestressing Strand
Sample Taken Date: 11/10/2015
Date that the sample was received by the laboratory/organization performing the testing: 11/13/2015
The quantity of what the sample constitutes: 6
A brief description of the sample: .6 Strand
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Stressteel
Comments: Unknown
Reel/Coil/Pack Number(s): 1302465145546, 1302465145548
Number of Coils: Unknown
Group Number: Unknown
Strand Diameter:
Grade: 270
Strand Specification: ASTM A 416
Heat Number(s): 30279
Mfg. Lot Number(s): Unknown
Manufacturer(s): Insteel
DIME Test ID: 2015-11-10-10-1
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete (Strand Diameter Check)
Verified Date: 05/12/2016
Date Tested: 11/17/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
2
|
Dia of the Center Wire (in) | Dia of the Outer Wire 1 (in) | Dia of the Outer Wire 2 (in) | Dia of the Outer Wire 3 (in) | Dia of the Outer Wire 4 (in) | Dia of the Outer Wire 5 (in) | Dia of the Outer Wire 6 (in) | Area (sqin) | .205 | .198 | .198 | .198 | .198 | .198 | .198 | 0.218 | .206 | .198 | .198 | .198 | .198 | .198 | .198 | 0.218 |
| |
DIME Test ID: 2015-11-10-10-2
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Verified Date: 05/12/2016
Date Tested: 11/17/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
2
|
Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By | 30279 | 1302465145546 | 0.218 | 61829 | 57098 | 28.6 | 1.74 | Dave | 30279 | 1302465145548 | 0.218 | 61416 | | 28.4 | 1.56 | Dave |
| |
UTM
|
120KIP
|
Temperature
|
70 F
|
Extensometers
|
E88768
|