Print Report | Back to Sample Detail

Sample Record for 2023-04-11-88

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 2720 DEA: 050N7204 EFIS: 0500000227 MINOR: 05A1245 QA Service Level: 1
DIST-CO-RTE-PM: 05---
Work Description:
Location Description:
Contractor Name: Robert J Frank Construction
Contractor Address: 2806 Tarmac Road, Redding, CA 96003
Resident Engineer: CHARLES HENCH Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-04-11-88
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Sample Organization Contact: (805) 621-3616
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/11/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/11/2023
The quantity of what the sample constitutes: 9 CY
A brief description of the sample: Concrete Test Samples
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CEMEX Santa Barbara

Material Information

The concrete mix design number: 1614705
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 30688245
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute discharge into wheel barrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 2

DIME Test ID: 2023-04-11-88-4
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 06/09/2023
Date Tested: 04/11/2023
Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Organization Address: 21 Griffin Road North,
Organization City: Windsor
Organization State: CT
Organization Zipcode: 06095-1590
Organization Email: dlachaine@trccompanies.com
Organization Phone: (805) 621-3616
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature 68 F

Test 2 of 2

DIME Test ID: 2023-04-11-88-5
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 06/09/2023
Date Tested: 04/11/2023
Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Organization Address: 21 Griffin Road North,
Organization City: Windsor
Organization State: CT
Organization Zipcode: 06095-1590
Organization Email: dlachaine@trccompanies.com
Organization Phone: (805) 621-3616
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Slump 6.25 inch

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-04-11-88-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates06/09/2023Not scheduledJesse GomezCT D05 - Carpinteria Field Laboratory
2023-04-11-88-2CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)06/09/2023Not scheduledJesse GomezCT D05 - Carpinteria Field Laboratory
2023-04-11-88-3CTM 217-June 2011: Method of Test for Sand Equivalent06/09/2023Not scheduledJesse GomezCT D05 - Carpinteria Field Laboratory