Print Report | Back to Sample Detail

Sample Record for 2023-05-07-13

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214820 DEA: 081K4604 EFIS: 0819000045 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-215-R36.6/R37.2
Work Description: ADD A S/B AND N/B AUX LANE
Location Description: RIVERSIDE COUNTY NEAR MORENO VALLEY FROM 0.2 MILE NORTH OF ALESSANDRO BOULEVARD OVERCROSSING TO 0.2 MILE SOUTH OF EUCALYPTUS AVENUE OVERCROSSING
Contractor Name: Riverside Construction Company
Contractor Address: 4225 Garner Road, Riverside CA, 92502
Resident Engineer: Paul Brown Structure Rep.: Hien Vu

Sample Information

DIME Sample ID: 2023-05-07-13
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 05/07/2023
Date that the sample was received by the laboratory/organization performing the testing: 05/16/2023
The quantity of what the sample constitutes: 6 Cores
A brief description of the sample: RHMA-G-SP 1/2"
From where was the sample collected: Manufacturer
Laboratory sample identification: 1A,1B,1C,2A,2B,2C
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: AAA Corona

Material Information

HMA Type: RHMA-G
HMA Grading: 1/2 inch
Lot number:
Sublot number:
HMA Mix Number: 106836

Test Results

Test 1 of 2

DIME Test ID: 2023-05-07-13-1
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/18/2023
Date Tested: 05/17/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Cores 1A, 1B, 1C
Test Result Compliance:
Additional Comments When Verified:
Number of tests 3
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.215
Specific Gravity for Sample 2 2.248
Specific Gravity for Sample 3 2.244
Average Specific Gravity 2.236
Theoretical maximum density at 25°C (77°F) 139.2 lb/ft^3

Test 2 of 2

DIME Test ID: 2023-05-07-13-3
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 05/18/2023
Date Tested: 05/17/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test: Cores 2A, 2B, 2C
Test Result Compliance:
Additional Comments When Verified:
Number of tests 3
What is the unit of measurement for theoretical density? US Units
Mass Determination Air
Specific Gravity for Sample 1 2.246
Specific Gravity for Sample 2 2.237
Specific Gravity for Sample 3 2.215
Average Specific Gravity 2.233
Theoretical maximum density at 25°C (77°F) 139.0 lb/ft^3