Print Report | Back to Sample Detail

Sample Record for 2015-10-13-10

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209187 DEA: 04235624 EFIS: 0400000678 COOP: 042583 QA Service Level: 1
DIST-CO-RTE-PM: 04-SCL,SM-101-52.0/52.6,0.0/0.6
Work Description: BRIDGE REPLACEMENT
Location Description: SANTA CLARA AND SAN MATEO COUNTIES IN PALO ALTO AND EAST PALO ALTO FROM OREGON EXPRESSWAY OVERCROSSING TO 0.3 MILE SOUTH OF UNIVERSITY AVENUE OVERCROSSING
Contractor Name: GHILOTTI BROS / RM HARRIS JV
Contractor Address: 525 JACOBY STREET, SAN RAFAEL CA 94901
Resident Engineer: Fernando Abela Structure Rep.: Yannaing Tun

Sample Information

DIME Sample ID: 2015-10-13-10
TL Number from the TL Form: Unknown
Sample Submitted By Organization: Summit Associates
Sample Organization Contact: (208) 908-3498
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 10/13/2015
Date that the sample was received by the laboratory/organization performing the testing: 10/14/2015
The quantity of what the sample constitutes: One Day of Concrete Pour
A brief description of the sample: Concrete aggregates 1 inch x No 4 coarse and sand
From where was the sample collected: Source
Laboratory sample identification: 150180
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Central Concrete Redwood City Plant

Material Information

Source Identification (SMARA, name of Pit or Job Site): 150180
The fabricator's/manufacturer's product name for the sample: C33 Fine Agg C33 No 57 Coarse Agg
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Belt cut of Coarse and Fine Aggregate at Source
Where the material sample would have been placed if not sampled: Bridge Deck
Primary Aggregate Nominal Size:
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 5

DIME Test ID: 2015-10-13-10-1
Test Method: ASTM C117-13: Standard Test Method for Materials Finer than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 10/23/2015
Date Tested: 10/16/2015
Submitted By Organization: Summit Associates
Organization Address: 2300 Clayton Road, Suite 1380,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: kittric.guest@summitcm.com
Organization Phone: 208-908-3498
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent finer than No. 200 sieve 0.8 %

Test 2 of 5

DIME Test ID: 2015-10-13-10-2
Test Method: ASTM D2419-09: Standard Test Method for Sand Equivalent Value of Soils and Fine Aggregate
Verified Date: 10/23/2015
Date Tested: 10/16/2015
Submitted By Organization: Summit Associates
Organization Address: 2300 Clayton Road, Suite 1380,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: kittric.guest@summitcm.com
Organization Phone: 208-908-3498
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 88

Test 3 of 5

DIME Test ID: 2015-10-13-10-3
Test Method: ASTM C566-13: Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
Verified Date: 10/23/2015
Date Tested: 10/16/2015
Submitted By Organization: Summit Associates
Organization Address: 2300 Clayton Road, Suite 1380,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: kittric.guest@summitcm.com
Organization Phone: 208-908-3498
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total evaporable moisture content 5.4 %

Test 4 of 5

DIME Test ID: 2015-10-13-10-4
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 10/23/2015
Date Tested: 10/16/2015
Submitted By Organization: Summit Associates
Organization Address: 2300 Clayton Road, Suite 1380,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: kittric.guest@summitcm.com
Organization Phone: 208-908-3498
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? 1 in. x No. 4 - Coarse Aggregate
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 99 %
Cumulative percent passing the 3/4 in. sieve 71 %
Cumulative percent passing the 1/2 in. sieve 34 %
Cumulative percent passing the 3/8 in. sieve 23 %
Cumulative percent passing the #4 sieve 4 %
Cumulative percent passing the #8 sieve 2 %

Test 5 of 5

DIME Test ID: 2015-10-13-10-5
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 10/23/2015
Date Tested: 10/16/2015
Submitted By Organization: Summit Associates
Organization Address: 2300 Clayton Road, Suite 1380,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: kittric.guest@summitcm.com
Organization Phone: 208-908-3498
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
What type of gradation is being tested? Fine Aggregate
Cumulative percent passing the 3/8 in. sieve 100 %
Cumulative percent passing the #4 sieve 98 %
Cumulative percent passing the #8 sieve 84 %
Cumulative percent passing the #16 sieve 67 %
Cumulative percent passing the #30 sieve 46 %
Cumulative percent passing the #50 sieve 24 %
Cumulative percent passing the #100 sieve 7 %
Cumulative percent passing the #200 sieve 1 %