Print Report | Back to Sample Detail

Sample Record for 2023-05-05-50

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214820 DEA: 081K4604 EFIS: 0819000045 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-215-R36.6/R37.2
Work Description: ADD A S/B AND N/B AUX LANE
Location Description: RIVERSIDE COUNTY NEAR MORENO VALLEY FROM 0.2 MILE NORTH OF ALESSANDRO BOULEVARD OVERCROSSING TO 0.2 MILE SOUTH OF EUCALYPTUS AVENUE OVERCROSSING
Contractor Name: Riverside Construction Company
Contractor Address: 4225 Garner Road, Riverside CA, 92502
Resident Engineer: Paul Brown Structure Rep.: Hien Vu

Sample Information

DIME Sample ID: 2023-05-05-50
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: 9512323690
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 05/05/2023
Date that the sample was received by the laboratory/organization performing the testing: 05/05/2023
The quantity of what the sample constitutes: 1 Bag
A brief description of the sample: 3/4 HMA-A-SP
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: All American Asphalt Corona

Material Information

Source Identification (SMARA, name of Pit or Job Site): 91-33-0005
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample: 105927
The plant number:
A detailed description of where the material sample was collected: Belt Cut @ AAA Corona
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:

Test Results

Test 1 of 2

DIME Test ID: 2023-05-05-50-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 05/15/2023
Date Tested: 05/09/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested? Combined Gradation
Cumulative percent passing the 2 in. sieve 100 %
Cumulative percent passing the 1 1/2 in. sieve 100 %
Cumulative percent passing the 1 in. sieve 100 %
Cumulative percent passing the 3/4 in. sieve 98 %
Cumulative percent passing the 1/2 in. sieve 82 %
Cumulative percent passing the 3/8 in. sieve 65 %
Cumulative percent passing the #4 sieve 39 %
Cumulative percent passing the #8 sieve 27 %
Cumulative percent passing the #16 sieve 19 %
Cumulative percent passing the #30 sieve 13 %
Cumulative percent passing the #50 sieve 8 %
Cumulative percent passing the #100 sieve 5 %
Cumulative percent passing the #200 sieve 3.6 %

Test 2 of 2

DIME Test ID: 2023-05-05-50-2
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 05/15/2023
Date Tested: 05/09/2023
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: prakash.gowda@dot.ca.gov
Organization Phone: (951) 232-3690
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Sand Equivalent 76