The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Cured in accordance with ASTM C511
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.03 | 28.56 | 150204 | 5259.2 | 1 |
2 | 6.02 | 28.46 | 152665 | 5364.2 | 1 |
DIME Test ID: 2015-10-13-8-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 5310
Age of specimen: 28 days
Certified By: Larry McCrum