Print Report | Back to Sample Detail

Sample Record for 2015-10-14-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209217 DEA: 080F5404 EFIS: 0800000136 COOP: 081468 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-91,15-0.0/13.04, 35.64/45.14
Work Description: SR-91 Corridor Improvement Project: Develop approx. 8 miles of tolled express lanes and related improvements within SR 91 between the Riverside/Orange County line and I-15, including transition areas.
Location Description: 08-RIV-91-0.0/13.04; 12-ORA-91-R14.43/R18.91; 08-RIV-15-35.64/45.14
Contractor Name: Atkinson Walsh, Joint Venture
Contractor Address: 1785 Sampson Ave, Corona, CA 92879
Resident Engineer: Richard Hebert Structure Rep.: Cyrus Shahinpar

Sample Information

DIME Sample ID: 2015-10-14-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 10/14/2015
Date that the sample was received by the laboratory/organization performing the testing: 10/16/2015
The quantity of what the sample constitutes: 5
A brief description of the sample: Bearing Pad
From where was the sample collected: Fabricator
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Scougal

Material Information

Mfg. Lot Number(s): 140971
Material/Compound/Elastomer ID: 140971
Samples Representing: 5
Description (size): 6in x 20in x 20in
Comments: Unknown
Description (Number of Shims): 12
Type of Bearing Pad: Steel
Description (Thickness of Shims): 14 gage
Manufacturer(s): Scougal
Batch Number: NA

Test Results

Test 1 of 4

DIME Test ID: 2015-10-14-1-1
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 10/20/2015
Date Tested: 10/16/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 72 f
Humidity 50 %
Reading #1 56
Reading #2 55
Reading #3 56
Reading #4 55
Reading #5 55
Mean 55.4

Test 2 of 4

DIME Test ID: 2015-10-14-1-2
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 10/20/2015
Date Tested: 10/16/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
Unit of the Ultimate Tensile Values lbf per sqr in
UTM no data
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.071 in
Sample 1 Thickness all Within 0.003 inch? yes
Sample 1 Ultimate Tensile 2359.6 lbf/in^2
Sample 1 Elongation (350% Min) Pass
Sample 2 Median Thickness 0.072 in
Sample 2 Thickness all Within 0.003 inch? yes
Sample 2 Ultimate Tensile 2444.4 lbf/in^2
Sample 2 Elongation (350% Min) Pass
Sample 3 Median Thickness 0.075 in
Sample 3 Thickness all Within 0.003 inch? yes
Sample 3 Ultimate Tensile 2872.3 lbf/in^2
Sample 3 Elongation (350% Min) Pass
Median of the Ultimate Tensile Values 2444.4 lbf/in^2

Test 3 of 4

DIME Test ID: 2015-10-14-1-3
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 10/20/2015
Date Tested: 10/16/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested 3
UTM no data
Humidity 50 %
Temperature 72 F
Sample 1 Median Thickness 0.072 in
Sample 1 Tear Strength 208.3 lbf / in
Sample 2 Median Thickness 0.071 in
Sample 2 Tear Strength 239.4 lbf / in
Sample 3 Median Thickness 0.076 in
Sample 3 Tear Strength 236.8 lbf / in
Median of the Tear Strength Values 236.8 lb/in

Test 4 of 4

DIME Test ID: 2015-10-14-1-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 10/20/2015
Date Tested: 10/19/2015
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Result Pass