Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994062 DEA: 010F5104 EFIS: 0116000015
QA Service Level: 1
DIST-CO-RTE-PM: 01-MEN,HUM-101-R106.2/T106.8
Work Description: SOUTH FORK EEL RIVER BRIDGE SEISMIC
Location Description: MENDOCINO AND HUMBOLDT COUNTIES NEAR COOKS VALLEY FROM 0.4 MILE SOUTH OF SOUTH FORK EEL RIVER BRIDGE TO 0.1 MILE NORTH OF ROUTE 271
Contractor Name: J.F. SHEA CONSTRUCTION, INC.
Contractor Address: 667 BREA CANYON ROAD, SUITE 3, WALNUT CA 91789
Resident Engineer: Joaquin Rodriguez Structure Rep.: George Moore
DIME Sample ID: 2023-05-05-30
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - District 1 Materials Laboratory
Sample Organization Contact: (707) 496-0974
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 05/05/2023
Date that the sample was received by the laboratory/organization performing the testing: 05/08/2023
The quantity of what the sample constitutes: Barrier Slab
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: C0152
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Mercer Fraser
The concrete mix design number: MFCLI 45Slag
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-05-05-30-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 06/16/2023
Date Tested: 06/16/2023
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test: 42 day Break
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
2
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
6.00 in
|
Average diameter of cylinder 2
|
6.00 in
|
Cross sectional area of cylinder 1
|
28.3 in^2
|
Cross sectional area of cylinder 2
|
28.3 in^2
|
Compressive strength (to nearest 10 psi)
|
5720 psi
|
Maximum load on cylinder 1
|
157260 lb
|
Maximum load on cylinder 2
|
165900 lb
|
Type of fracture pattern of cylinder 1
|
5
|
Type of fracture pattern of cylinder 2
|
5
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Age of specimen
|
42 days
|
Age of specimen in hours
|
0 hours
|