Print Report | Back to Sample Detail

Sample Record for 2023-04-25-58

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994777 DEA: 041J7804 EFIS: 0414000357 QA Service Level: 1
DIST-CO-RTE-PM: 04-ALA-24,80,680,880-VAR
Work Description:
Location Description: FOR CONSTRUCTION ON STATE HIGHWAY IN ALAMEDA AND CONTRA COSTA COUNTIES AT VARIOUS LOCATIONS
Contractor Name: O.C. JONES & SONS INC.
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-04-25-58
TL Number from the TL Form: C422-310
Sample Submitted By Organization: CT D04 - Concord Field Laboratory
Sample Organization Contact: (510) 714-7019
Type of Sample: Quality Assurance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/25/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/26/2023
The quantity of what the sample constitutes: Production Start Up Evaluation
A brief description of the sample: 1/2 RHMA-O
From where was the sample collected: Manufacturer
Laboratory sample identification: Con_23_356
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DeSilva Gates Aggregates

Material Information

HMA Type: OGFC
HMA Grading: 1/2 inch
Lot number: 1
Sublot number: 1
HMA Mix Number: MD 6653

Test Results

Test 1 of 1

DIME Test ID: 2023-04-25-58-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 05/09/2023
Date Tested: 04/28/2023
Submitted By Organization: CT D04 - Concord Field Laboratory
Organization Address: 2525 Stanwell Drive, Suite 100,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: gurind.joshi@dot.ca.gov
Organization Phone: (510) 714-7019
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of the specimen basket assembly 3154.2 g
Mass of the specimen and specimen basket assembly prior to ignition 4758.5 g
Mass of HMA Sample prior to ignition 1604.3 g
Corrected Asphalt Binder Content 7.78 %
Mass Loss 142.6 g
Mass of aggregate remaining after ignition 1461.7 g
Correction Factor (Percent by mass of HMA Specimen) 0.97 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.14 %
Test Temperature 538 C