Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 212737 DEA: 060S8304 EFIS: 0615000046
QA Service Level: 1
DIST-CO-RTE-PM: 06-FRE-5-44.4-45.4
Work Description: TUMEY GULCH ABUTMENT REHAB BR# 42-0246L/R.
Location Description: IN FRESNO COUNTY AT TUMEY GULCH.
Contractor Name: Bruce Shumacher
Contractor Address: 2716 S Granite Ct, Fresno, CA 93706
Resident Engineer: Cary Cruz Structure Rep.: Ben Holton
DIME Sample ID: 2023-04-27-21
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Millbrook Field Laboratory
Sample Organization Contact: (559) 417-5341
Type of Sample: Verification
Type of Material: Aggregate
Sample Taken Date: 04/27/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/27/2023
The quantity of what the sample constitutes: 2000 yd2
A brief description of the sample: AC grindings
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Travel way South of bridge
The fabricator/manufacturer/facility name: Jobsite
Source Identification (SMARA, name of Pit or Job Site): Jobsite
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number:
A detailed description of where the material sample was collected: Travel way south of bridge
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 1 inch
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
DIME Test ID: 2023-04-27-21-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 04/28/2023
Date Tested: 04/27/2023
Submitted By Organization: CT D06 - Millbrook Field Laboratory
Organization Address: 3240 North Millbrook Avenue,
Organization City: Fresno
Organization State: CA
Organization Zipcode: 93726
Organization Email: tomas.silva@dot.ca.gov
Organization Phone: (559) 417-5341
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Standard Count Density
|
1832 g/cc
|
Count or Density 1
|
987 g/cc
|
Count or Density 2
|
986 g/cc
|
Count or Density 3
|
1141 g/cc
|
Standard Count Moisture
|
615 g/cc
|
Moisture Count 1
|
172 g/cc
|
Moisture Count 2
|
164 g/cc
|
Moisture Count 3
|
135 g/cc
|
Sum of Count or Density
|
3114.00 g/cc
|
Average of Count or Density
|
1038.00 g/cc
|
Sum of Moisture Count
|
471.00 g/cc
|
Average of Moisture Count
|
157.00 g/cc
|
Count Ratio Density
|
0.57
|
Count Ratio Moisture
|
0.26
|
Calculated Percent Relative Compaction
|
97.7 %
|
Reported Percent Relative Compaction
|
98 %
|