Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215180 DEA: 060Q9204 EFIS: 0614000010 COOP: 061764
QA Service Level: 1
DIST-CO-RTE-PM: 06-KER-99-10.4/21.2
Work Description: CONSTRUCT CRCP AND HMA (TYPE A) PAVEMENT.
Location Description: KERN COUNTY IN AND NEAR BAKERSFIELD FROM 0.4 MILE SOUTH OF OLD US 99 OVERCROSSING TO 0.1 MILE NORTH OF WHITE LANE OVERCROSSING
Contractor Name: Griffith Company
Contractor Address: 1128 Carrier Parkway, Bakersfield ,CA 93308
Resident Engineer: James Burford Structure Rep.: Ulysis Baal
DIME Sample ID: 2023-04-25-19
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Sample Organization Contact: 661-549-8281
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/25/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/26/2023
The quantity of what the sample constitutes: 750 tons L1SL88
A brief description of the sample: 3/4 HMA-SP Type A
From where was the sample collected: Source
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Griffith Edmonston
DIME Test ID: 2023-04-25-19-1
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Verified Date: 04/26/2023
Date Tested: 04/26/2023
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Number of Samples
|
1
|
What is the unit of measurement for theoretical density?
|
SI Units
|
Mass Determination
|
Air
|
Method Performed
|
Mechanical Agitation - Method A
|
Mass of container filled with water 1
|
7328.4 grams
|
Mass of oven-dry sample in air for Sample 1
|
2583.3 grams
|
Mass of container filled with the sample and water for Sample 1
|
8916.4 grams
|
Temperature of Water
|
77 °F
|
Specific Gravity for Sample 1
|
2.595
|
Theoretical maximum density at 25°C (77°F)
|
2587.5 kg/m^3
|
DIME Test ID: 2023-04-25-19-2
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/26/2023
Date Tested: 04/26/2023
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test: L1SL88
Test Result Compliance:
Additional Comments When Verified:
What temperature unit is used?
|
Fahrenheit
|
Test procedure used?
|
Method A
|
Mass of the specimen basket assembly
|
4299.5 g
|
Mass of the specimen and specimen basket assembly prior to ignition
|
6378.9 g
|
Mass of HMA Sample prior to ignition
|
2079.4 g
|
Corrected Asphalt Binder Content
|
4.73 %
|
Mass Loss
|
107.2 g
|
Mass of aggregate remaining after ignition
|
1972.2 g
|
Correction Factor (Percent by mass of HMA Specimen)
|
0.43 %
|
Moisture Content
|
0.00 %
|
Temperature Compensation Factor
|
0.00 %
|
Test Temperature
|
538 F
|
DIME Test ID: 2023-04-25-19-3
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Verified Date: 04/28/2023
Date Tested: 04/27/2023
Submitted By Organization: CT D06 - Bakersfield Field Laboratory
Organization Address: 1824 Norris Road,
Organization City: Bakersfield
Organization State: CA
Organization Zipcode: 93308
Organization Email: kulwinder.rai@dot.ca.gov
Organization Phone: (661) 549-8281
General Comments for this Test: L1SL88 88A=93.4, 88B=94.2, 88C= 94.0
Test Result Compliance: complies
Additional Comments When Verified:
Bulk Specific Gravity
|
2.373
|
Bulk Specific Gravity 2
|
2.400
|
Bulk Specific Gravity 3
|
2.393
|
Average Bulk Specific Gravity
|
2.389
|