Sample Record for 2015-09-22-11
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 209187 DEA: 04235624 EFIS: 0400000678 COOP: 042583
QA Service Level: 1
DIST-CO-RTE-PM: 04-SCL,SM-101-52.0/52.6,0.0/0.6
Work Description: BRIDGE REPLACEMENT
Location Description: SANTA CLARA AND SAN MATEO COUNTIES IN PALO ALTO AND EAST PALO ALTO FROM OREGON EXPRESSWAY OVERCROSSING TO 0.3 MILE SOUTH OF UNIVERSITY AVENUE OVERCROSSING
Contractor Name: GHILOTTI BROS / RM HARRIS JV
Contractor Address: 525 JACOBY STREET, SAN RAFAEL CA 94901
Resident Engineer: Fernando Abela Structure Rep.: Yannaing Tun
Sample Information
DIME Sample ID: 2015-09-22-11
TL Number from the TL Form: Unknown
Sample Submitted By Organization: Summit Associates
Sample Organization Contact: (208) 908-3498
Type of Sample: Quality Control
Type of Material: Aggregate
Sample Taken Date: 09/22/2015
Date that the sample was received by the laboratory/organization performing the testing: 09/23/2015
The quantity of what the sample constitutes: One Day of Concrete Pour
A brief description of the sample: Concrete aggregates 3/4 inch coarse and sand
From where was the sample collected: Source
Laboratory sample identification: 150160
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Central Concrete Redwood City Plant
Material Information
Source Identification (SMARA, name of Pit or Job Site): 150160
The fabricator's/manufacturer's product name for the sample: C33 Fine Agg C33 67 Coarse Agg
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: Belt cut of Coarse and Fine Aggregate at Source
Where the material sample would have been placed if not sampled: Abutment 1 Wall Pier 2 Wall Pier 4 Footing
Primary Aggregate Nominal Size:
The concrete mix design number:
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 5
DIME Test ID: 2015-09-22-11-1
Test Method: ASTM C117-13: Standard Test Method for Materials Finer than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 10/07/2015
Date Tested: 09/29/2015
Submitted By Organization: Summit Associates
Organization Address: 2300 Clayton Road, Suite 1380,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: kittric.guest@summitcm.com
Organization Phone: 208-908-3498
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Percent finer than No. 200 sieve
|
0.5 %
|
Test 2 of 5
DIME Test ID: 2015-09-22-11-2
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 10/07/2015
Date Tested: 09/29/2015
Submitted By Organization: Summit Associates
Organization Address: 2300 Clayton Road, Suite 1380,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: kittric.guest@summitcm.com
Organization Phone: 208-908-3498
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested?
|
1 in. x No. 4 - Coarse Aggregate
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
90 %
|
Cumulative percent passing the 1/2 in. sieve
|
66 %
|
Cumulative percent passing the 3/8 in. sieve
|
41 %
|
Cumulative percent passing the #4 sieve
|
4 %
|
Cumulative percent passing the #8 sieve
|
1 %
|
Test 3 of 5
DIME Test ID: 2015-09-22-11-3
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Verified Date: 10/07/2015
Date Tested: 09/29/2015
Submitted By Organization: Summit Associates
Organization Address: 2300 Clayton Road, Suite 1380,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: kittric.guest@summitcm.com
Organization Phone: 208-908-3498
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What type of gradation is being tested?
|
Fine Aggregate
|
Cumulative percent passing the 3/8 in. sieve
|
100 %
|
Cumulative percent passing the #4 sieve
|
100 %
|
Cumulative percent passing the #8 sieve
|
89 %
|
Cumulative percent passing the #16 sieve
|
62 %
|
Cumulative percent passing the #30 sieve
|
36 %
|
Cumulative percent passing the #50 sieve
|
16 %
|
Cumulative percent passing the #100 sieve
|
4 %
|
Cumulative percent passing the #200 sieve
|
1 %
|
Test 4 of 5
DIME Test ID: 2015-09-22-11-4
Test Method: ASTM C566-13: Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
Verified Date: 10/07/2015
Date Tested: 09/29/2015
Submitted By Organization: Summit Associates
Organization Address: 2300 Clayton Road, Suite 1380,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: kittric.guest@summitcm.com
Organization Phone: 208-908-3498
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Total evaporable moisture content
|
7.5 %
|
Test 5 of 5
DIME Test ID: 2015-09-22-11-5
Test Method: ASTM D2419-09: Standard Test Method for Sand Equivalent Value of Soils and Fine Aggregate
Verified Date: 10/07/2015
Date Tested: 09/29/2015
Submitted By Organization: Summit Associates
Organization Address: 2300 Clayton Road, Suite 1380,
Organization City: Concord
Organization State: CA
Organization Zipcode: 94520
Organization Email: kittric.guest@summitcm.com
Organization Phone: 208-908-3498
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: