Sample Record for 2023-03-07-46
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 994093 DEA: 07342804 EFIS: 0717000331
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-14-R27.0/R28.1
Work Description: CONSTRUCT CATCHMENT WALL, ROCK SCALING AND CONCRETE BARRIER.
Location Description: LOS ANGELES COUNTY IN SANTA CLARITA FROM THE NEWHALL AVENUE UNDERCROSSING TO 0.1 MILE SOUTH OF PLACERITA CANYON ROAD UNDERCROSSING
Contractor Name: Powell Constructors, Inc.
Contractor Address: 8555 Banana Avenue, Fontana, CA, 92335
Resident Engineer: Ali MOHSENZADEH Structure Rep.: Unknown
Sample Information
DIME Sample ID: 2023-03-07-46
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM1 - Elastomeric Bearing Pad
Sample Taken Date: 03/07/2023
Date that the sample was received by the laboratory/organization performing the testing: 03/30/2023
The quantity of what the sample constitutes: 50
A brief description of the sample: Bearing Pad
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: D.S. Brown
Material Information
Mfg. Lot Number(s): 1065394-1102-2A-2
Material/Compound/Elastomer ID: NA
Samples Representing: 50
Description (size): 48"x6"x.5"
Comments:
Description (Number of Shims): 0
Type of Bearing Pad: Plain
Description (Thickness of Shims): NA
Manufacturer(s): DS Brown
Batch Number: NA
Test Results
Test 1 of 4
DIME Test ID: 2023-03-07-46-1
Test Method: ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer Hardness
Verified Date: 04/24/2023
Date Tested: 04/19/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature
|
72 f
|
Humidity
|
50 %
|
Reading #1
|
56
|
Reading #2
|
55
|
Reading #3
|
57
|
Reading #4
|
55
|
Reading #5
|
58
|
Mean
|
56.2
|
Test 2 of 4
DIME Test ID: 2023-03-07-46-2
Test Method: ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Verified Date: 04/24/2023
Date Tested: 04/19/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
Unit of the Ultimate Tensile Values
|
lbf per sqr in
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.07
|
Sample 1 Thickness all Within 0.003 inch?
|
Yes
|
Sample 1 Ultimate Tensile
|
2566.92 lbf/in^2
|
Sample 1 Elongation (350% Min)
|
Pass
|
Sample 2 Median Thickness
|
0.07
|
Sample 2 Thickness all Within 0.003 inch?
|
Yes
|
Sample 2 Ultimate Tensile
|
2562.25 lbf/in^2
|
Sample 2 Elongation (350% Min)
|
Pass
|
Sample 3 Median Thickness
|
0.073
|
Sample 3 Thickness all Within 0.003 inch?
|
Yes
|
Sample 3 Ultimate Tensile
|
2691.73 lbf/in^2
|
Sample 3 Elongation (350% Min)
|
Pass
|
Median of the Ultimate Tensile Values
|
2566.9 lbf/in^2
|
Test 3 of 4
DIME Test ID: 2023-03-07-46-3
Test Method: ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Verified Date: 04/24/2023
Date Tested: 04/19/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of specimens tested
|
3
|
UTM
|
2kip
|
Humidity
|
50.00 %
|
Temperature
|
72 F
|
Sample 1 Median Thickness
|
0.08
|
Sample 1 Tear Strength
|
267
|
Sample 2 Median Thickness
|
0.081
|
Sample 2 Tear Strength
|
242.8
|
Sample 3 Median Thickness
|
0.081
|
Sample 3 Tear Strength
|
318.2
|
Median of the Tear Strength Values
|
267 lb/in
|
Test 4 of 4
DIME Test ID: 2023-03-07-46-4
Test Method: SMTL BILST-06: (Neoprene Verification) Bilstein Test
Verified Date: 04/20/2023
Date Tested: 04/20/2023
Submitted By Organization: CT HQ - Sacramento Chemistry Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: sanchita.dey@dot.ca.gov
Organization Phone: (916) 227-7912
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified: