Print Report | Back to Sample Detail

Sample Record for 2023-04-06-27

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212112 DEA: 080C2514 EFIS: 0816000076 COOP: 081645 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-0.0/13.2
Work Description: Design-Build of I-10 Corridor Contract 1 - Adding 2 new Express Lanes
Location Description: LA/SBD County Line to PM 13.2 near I-15
Contractor Name: Lane-Security Paving Joint Venture
Contractor Address: 3450 Centre Lake Drive, 1st Floor, Ontario, CA 91761
Resident Engineer: Jose Corona Structure Rep.: Luis Negrete

Sample Information

DIME Sample ID: 2023-04-06-27
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Department Acceptance
Type of Material: Hot Mix Asphalt
Sample Taken Date: 04/06/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/13/2023
The quantity of what the sample constitutes: 2 boxes of HMA 116.48 tons out
A brief description of the sample: 3/4" HMA-A-SP R15 0.75% LAS
From where was the sample collected: Manufacturer
Laboratory sample identification: 0203A-23
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Irwindale

Material Information

HMA Type: Type A HMA
HMA Grading: 3/4 inch
Lot number: 5
Sublot number: 39
HMA Mix Number: 220831A IRW SJR LS

Test Results

Test 1 of 1

DIME Test ID: 2023-04-06-27-1
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Verified Date: 04/21/2023
Date Tested: 04/14/2023
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: (909) 829-3029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
What temperature unit is used? Celsius
Test procedure used? Method A
Mass of HMA Sample prior to ignition 2138.5 g
Corrected Asphalt Binder Content 4.65 %
Mass Loss 116.0 g
Correction Factor (Percent by mass of HMA Specimen) 0.63 %
Moisture Content 0.00 %
Temperature Compensation Factor 0.00 %
Test Temperature 538 C