Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 213598 DEA: 051F75U4 EFIS: 0518000092
QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-101-R36.9/47.7
Work Description: CRCP, SEISMIC RETROFIT, BRIDGE WIDENING AND MEDIAN BARRIER
Location Description: MONTEREY COUNTY IN AND NEAR KING CITY FROM 0.4 MILE SOUTH OF WILD HORSE ROAD OVERCROSSING TO TEAGUE AVENUE
Contractor Name: OHL USA, INC.
Contractor Address: 1920 Main St. Suite 310, Irvine, CA 92614
Resident Engineer: Adam Rianda Structure Rep.: Unknown
DIME Sample ID: 2023-04-04-27
TL Number from the TL Form: Sacramento Caltrans lab
Sample Submitted By Organization: Kwik Bond Polymers
Sample Organization Contact: (760) 518-6064
Type of Sample: Quality Control
Type of Material: Polyester
Sample Taken Date: 04/04/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/06/2023
The quantity of what the sample constitutes: 36 Totes
A brief description of the sample: 1 gallon can
From where was the sample collected: Source
Laboratory sample identification: 943770
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Kwik Bond Polymers, Benicia
DIME Test ID: 2023-04-04-27-1
Test Method: ASTM D2196-Feb15: Standard Test Methods for Rheological Properties of Non-Newtonian Materials by Rotational Viscometer
Verified Date: 07/14/2023
Date Tested: 04/21/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
DIME Test ID: 2023-04-04-27-2
Test Method: ASTM D1475-Nov13: Standard Test Method For Density of Liquid Coatings, Inks, and Related Products
Verified Date: 07/14/2023
Date Tested: 04/21/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Density Units
|
pounds/gallons
|
Liquid Density (pounds per gallon)
|
9
|
DIME Test ID: 2023-04-04-27-3
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Verified Date: 07/14/2023
Date Tested: 04/10/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted supplier's results.
Test Result Compliance: complies
Additional Comments When Verified:
Number of specimens tested
|
6
|
Conditioning procedure
|
18/25/50+5/70
|
Speed of testing
|
0.45 in/min
|
Sample 1 Width
|
0.488 in
|
Sample 1 Ultimate strength
|
2864.1 psi
|
Sample 1 Thickness
|
0.255 in
|
Sample 1 Area
|
0.1244 in^2
|
Sample 1 Ultimate Strength Actual
|
356.3 lbs
|
Sample 1 percent elongation
|
48.9 %
|
Sample 1 Time
|
0 MM:SS
|
Sample 2 Width
|
0.488 in
|
Sample 2 Thickness
|
0.245 in
|
Sample 2 Area
|
0.1196 in^2
|
Sample 2 Ultimate strength
|
2852 psi
|
Sample 2 Ultimate Strength Actual
|
341.1 lbs
|
Sample 2 percent elongation
|
50.6 %
|
Sample 2 Time
|
0 MM:SS
|
Sample 3 Width
|
0.487 in
|
Sample 3 Thickness
|
0.249 in
|
Sample 3 Area
|
0.1213 in^2
|
Sample 3 Ultimate strength
|
2830.2 psi
|
Sample 3 Ultimate Strength Actual
|
343.3 lbs
|
Sample 3 percent elongation
|
53.8 %
|
Sample 3 Time
|
0 MM:SS
|
Sample 4 Width
|
0.487 in
|
Sample 4 Thickness
|
0.248 in
|
Sample 4 Area
|
0.1208 in^2
|
Sample 4 Ultimate strength
|
2821.2 psi
|
Sample 4 Ultimate Strength Actual
|
340.8 lbs
|
Sample 4 percent elongation
|
47.5 %
|
Sample 4 Time
|
0 MM:SS
|
Sample 5 Width
|
0.487 in
|
Sample 5 Thickness
|
0.251 in
|
Sample 5 Area
|
0.1222 in^2
|
Sample 5 Ultimate strength
|
2820.8 psi
|
Sample 5 Ultimate Strength Actual
|
344.7 lbs
|
Sample 5 percent elongation
|
46.3 %
|
Sample 5 Time
|
0 MM:SS
|
Sample 6 Width
|
0.487 in
|
Sample 6 Thickness
|
0.253 in
|
Sample 6 Area
|
0.1232 in^2
|
Sample 6 Ultimate strength
|
2802.8 psi
|
Sample 6 Ultimate Strength Actual
|
345.3 lbs
|
Sample 6 percent elongation
|
52.6 %
|
Sample 6 Time
|
0 MM:SS
|
Ultimate Strength Average
|
2832 psi
|
Percent Elongation Average
|
50 %
|
DIME Test ID: 2023-04-04-27-4
Test Method: ASTM D2369-Jul10: Standard Test Method for Volatile Content of Coatings
Verified Date: 07/14/2023
Date Tested: 04/21/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Mean of two volatile content determination
|
45.8
|
DIME Test ID: 2023-04-04-27-5
Test Method: CTM 551-August 2012: Method of Test for Determining Suitability of Materials for Overlayment and Repair of Portland Cement Concrete Pavements and Structures
Verified Date: 07/14/2023
Date Tested: 04/11/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted supplier's results.
Test Result Compliance: complies
Additional Comments When Verified:
Curing history for Sample 1
|
24hr
|
Maximum applied load (P) for Sample 1
|
1320 lb
|
Span length for Sample 1
|
9 in
|
Break location for Sample 1
|
bond
|
Specimen defects/notes for Sample 1
|
no data
|
Surface type for Sample 1
|
SSD
|
Modulus of rupture (R) for Sample 1
|
660 psi
|
Curing history for Sample 2
|
24hr
|
Maximum applied load (P) for Sample 2
|
1424.6 lb
|
Span length for Sample 2
|
9 in
|
Break location for Sample 2
|
bond
|
Specimen defects/notes for Sample 2
|
no data
|
Surface type for Sample 2
|
SSD
|
Modulus of rupture (R) for Sample 2
|
712.3 psi
|
Curing history for Sample 3
|
24hr
|
Maximum applied load (P) for Sample 3
|
1414.2 lb
|
Span length for Sample 3
|
9 in
|
Break location for Sample 3
|
bond
|
Specimen defects/notes for Sample 3
|
no data
|
Surface type for Sample 3
|
SSD
|
Modulus of rupture (R) for Sample 3
|
707.1 psi
|
DIME Test ID: 2023-04-04-27-6
Test Method: SCAQMD 309-91-Feb93: Determination of Static Volatile Emissions
Verified Date: 07/14/2023
Date Tested: 04/11/2023
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: spencer.adams@dot.ca.gov
Organization Phone: (916) 227-5716
General Comments for this Test: Accepted supplier's results.
Test Result Compliance: complies
Additional Comments When Verified:
Diameter of lid
|
153.9 mm
|
Room Temperature
|
77 f
|
Tare weight
|
no data
|
Initial weight
|
100.066 grams
|
Weight at 5 minutes
|
100 grams
|
Weight at 10 minutes
|
99.94 grams
|
Weight at 15 minutes
|
99.88 grams
|
Weight at 20 minutes
|
99.82 grams
|
Weight at 25 minutes
|
99.76 grams
|
Weight at 30 minutes
|
99.7 grams
|
Final weight
|
99.7 grams
|
Total weight loss
|
0.37 grams
|
Calculated radius of gallon can lid in cm
|
7.695 cm
|
Lid Factor
|
53.757 m^2
|
Volatile emission
|
19.675 grams/m^2
|