Print Report | Back to Sample Detail

Sample Record for 2023-04-08-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214135 DEA: 09213404 EFIS: 0900000030 QA Service Level: 1
DIST-CO-RTE-PM: 09-INY-395-29.9/41.8
Work Description: ROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT.
Location Description: INYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE
Contractor Name: FISHER SAND & GRAVEL CO.
Contractor Address: 1302 W DRIVERS WAY, TEPE, AZ. 85284
Resident Engineer: Kris Raber Structure Rep.: Alex Naime-Falcon

Sample Information

DIME Sample ID: 2023-04-08-3
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 04/08/2023
Date that the sample was received by the laboratory/organization performing the testing: 04/11/2023
The quantity of what the sample constitutes: 10CY
A brief description of the sample: LA Aqueduct South side Splash Wall and Footing
From where was the sample collected: Source
Laboratory sample identification: 48-88
Structure unique identifier:
Structure name: Los Angeles Aqueduct Bridge
The fabricator/manufacturer/facility name: 711 Materials Ridgecrest

Material Information

The concrete mix design number: OV-10P
The truck number from where the sample was collected: 4001
The batch plant ticket number from where the sample was collected: 19
Concrete batch plant: 711 Materials Ridgecrest
The fabricator/manufacturer designation for the sample: District 9 lab
A detailed description of where the material sample was collected: LA Aqueduct Splash Wall
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-04-08-3-2
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617 - Sulfur Mortar Cap
Verified Date: 05/08/2023
Date Tested: 05/06/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: Break 3 at 28days
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Compressive strength (to nearest 10 psi) 4250 psi
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Compressive strength of cylinder 1 4210.8 psi
Compressive strength of cylinder 2 4156.7 psi
Average diameter of cylinder 3 4.00 in
Compressive strength of cylinder 3 4378.7 psi
Maximum load on cylinder 1 52930 lb
Maximum load on cylinder 2 52250 lb
Maximum load on cylinder 3 55040 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-04-08-3-3ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens04/11/202306/03/2023Sheila ReyesCT D09 - Bishop Field LaboratoryBreak 3 at 56days