Project ID: 993301 DEA: 060U2804 EFIS: 0615000293
QA Service Level: 1
DIST-CO-RTE-PM: 06-TUL-245-1.4,4.2
Work Description: PRECAST PRESTRESSED CONCRETE BOX GIRDER AND SLAB, BRIDGE REMOVAL.
Location Description: TULARE COUNTY NEAR WOODLAKE AT YOKOHL CREEK BRIDGE AND AT KAWEAH RIVER BRIDGE
Contractor Name: MCM Construction
Contractor Address: PO Box 620, North Highlands, Ca 95660
Resident Engineer: Mike Garrett Structure Rep.: Benajamin Holton
DIME Sample ID: 2022-12-22-62
TL Number from the TL Form:
Sample Submitted By Organization: CT D06 - Visalia Field Laboratory
Sample Organization Contact: (559) 341-4165
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/22/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/12/2022
The quantity of what the sample constitutes: 90 CY
A brief description of the sample: Type II Cement Concrete Agg
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Tul 245 Kaweah- Yokohl Bridges Wood Land
The fabricator/manufacturer/facility name: Viking Ready Mix Visalia
The concrete mix design number: ND22023
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: 897510
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Job site
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:
DIME Test ID: 2022-12-22-62-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/03/2023
Date Tested: 01/03/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 West Roosevelt Avenue,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: shoaib.ahmed@dot.ca.gov
Organization Phone: (559) 341-4165
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C617 - Sulfur Mortar Cap
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
4370 psi
|
Maximum load on cylinder 1
|
56916 lb
|
Maximum load on cylinder 2
|
53092 lb
|
Maximum load on cylinder 3
|
54919 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
2
|
Type of fracture pattern of cylinder 3
|
3
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
12 days
|
Age of specimen in hours
|
0 hours
|
DIME Test ID: 2022-12-22-62-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 04/04/2023
Date Tested: 01/19/2023
Submitted By Organization: CT D06 - Visalia Field Laboratory
Organization Address: 8530 West Roosevelt Avenue,
Organization City: Visalia
Organization State: CA
Organization Zipcode: 93291
Organization Email: shoaib.ahmed@dot.ca.gov
Organization Phone: (559) 341-4165
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
ASTM C1231 - Unbonded Elastomeric Pad Cap
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
5310 psi
|
Maximum load on cylinder 1
|
64027 lb
|
Maximum load on cylinder 2
|
65840 lb
|
Maximum load on cylinder 3
|
70201 lb
|
Type of fracture pattern of cylinder 1
|
2
|
Type of fracture pattern of cylinder 2
|
2
|
Type of fracture pattern of cylinder 3
|
2
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1
|
Correction factor for cylinder 2
|
1
|
Correction factor for cylinder 3
|
1
|
Age of specimen
|
28 days
|
Age of specimen in hours
|
0 hours
|