Project ID: 215691 DEA: 09377104 EFIS: 0918000041
QA Service Level: 1
DIST-CO-RTE-PM: 09-KER-5713,5755-
Work Description: REMODEL MAINTENANCE STATION AND RELOCATE FUEL TANK.
Location Description: KERN COUNTY AT MOJAVE AT THE MOJAVE SPECIAL CREWS BUILDING AT 1365 BUSINESS ROUTE 58 AND AT THE MOJAVE MAINTENANCE STATION AT 2211 NADEAU STREET
Contractor Name: RE COM DEVELOPMENT COMPANY
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Alex Naime
DIME Sample ID: 2023-03-27-22
TL Number from the TL Form:
Sample Submitted By Organization: CT D09 - Bishop Field Laboratory
Sample Organization Contact: (760) 872-5211
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 03/27/2023
Date that the sample was received by the laboratory/organization performing the testing: 03/28/2023
The quantity of what the sample constitutes: 1 1/2 CY
A brief description of the sample: Mix Design 3F40L003
From where was the sample collected: Job Site
Laboratory sample identification: D9
Structure unique identifier: 09-377104
Structure name: Mojave Special Crews Building
The fabricator/manufacturer/facility name: Holliday Rock, Tehachapi Ca.
The concrete mix design number: 3F40L003
The truck number from where the sample was collected: 813
The batch plant ticket number from where the sample was collected: 112029950
Concrete batch plant: Holliday Rock Company
The fabricator/manufacturer designation for the sample: Batch Plant
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled: north concrete curb
From Lot No.:
Bag Lot No.:
DIME Test ID: 2023-03-27-22-1
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 07/11/2023
Date Tested: 05/24/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: taken from curb at wall doorway of room 10
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
no data
|
Apparent mass of submerged cylinder 1
|
1 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
4040 psi
|
Maximum load on cylinder 1
|
51655 lb
|
Maximum load on cylinder 2
|
50845 lb
|
Maximum load on cylinder 3
|
49835 lb
|
Compressive strength of cylinder 1
|
4110.0 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
4040.0 psi
|
Compressive strength of cylinder 3
|
3960 psi
|
Type of fracture pattern of cylinder 2
|
1
|
Type of fracture pattern of cylinder 3
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Correction factor for cylinder 2
|
1.00
|
Correction factor for cylinder 3
|
1.00
|
Age of specimen
|
56 days
|
Age of specimen in hours
|
0 hours
|
Serial number of delivery ticket, if available
|
no data
|
DIME Test ID: 2023-03-27-22-2
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 05/03/2023
Date Tested: 04/24/2023
Submitted By Organization: CT D09 - Bishop Field Laboratory
Organization Address: 500 South Main Street,
Organization City: Bishop
Organization State: CA
Organization Zipcode: 93514
Organization Email: chris.talbot@dot.ca.gov
Organization Phone: (760) 872-0794
General Comments for this Test: 3 at 28 and 3 on hold
Test Result Compliance:
Additional Comments When Verified:
Unit system used?
|
US Units
|
Number of specimens
|
3
|
Test performed
|
With no density determined
|
Capped in accordance with?
|
no data
|
Apparent mass of submerged cylinder 1
|
0 lb
|
Average diameter of cylinder 1
|
4.00 in
|
Average diameter of cylinder 2
|
4.00 in
|
Average diameter of cylinder 3
|
4.00 in
|
Cross sectional area of cylinder 1
|
12.57 in^2
|
Cross sectional area of cylinder 2
|
12.57 in^2
|
Cross sectional area of cylinder 3
|
12.57 in^2
|
Compressive strength (to nearest 10 psi)
|
3510 psi
|
Maximum load on cylinder 1
|
43440 lb
|
Maximum load on cylinder 2
|
45080 lb
|
Maximum load on cylinder 3
|
43920 lb
|
Compressive strength of cylinder 1
|
3455.8 psi
|
Type of fracture pattern of cylinder 1
|
1
|
Compressive strength of cylinder 2
|
3586.3 psi
|
Compressive strength of cylinder 3
|
3494 psi
|
Type of fracture pattern of cylinder 2
|
1
|
Type of fracture pattern of cylinder 3
|
1
|
Comment on any defect in either specimen or caps (Max 250 Characters)
|
no data
|
Correction factor for cylinder 1
|
1.00
|
Correction factor for cylinder 2
|
1.00
|
Correction factor for cylinder 3
|
1.00
|
Age of specimen
|
0 days
|
Age of specimen in hours
|
0 hours
|
Serial number of delivery ticket, if available
|
no data
|