Print Report | Back to Sample Detail

Sample Record for 2023-02-22-60

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 994087 DEA: 051G4104 EFIS: 0515000012 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-4.0/4.8
Work Description: Santa Claus Lane Bike Path - !!Charge time to 05-0N72U4 per Project Manager / Corridor Manager!!
Location Description: !!Charge time to 05-0N72U4 per Project Manager / Corridor Manager!!
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5335 Debbie Road, Santa Barbara, CA 93111
Resident Engineer: Luobao Cai Structure Rep.: Josh Madrigal

Sample Information

DIME Sample ID: 2023-02-22-60
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Sample Organization Contact: (805) 621-3616
Type of Sample: Acceptance
Type of Material: Concrete
Sample Taken Date: 02/22/2023
Date that the sample was received by the laboratory/organization performing the testing: 03/22/2023
The quantity of what the sample constitutes: 9.5 CY
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta Goleta

Material Information

The concrete mix design number: 725A1Z0P
The truck number from where the sample was collected: 516
The batch plant ticket number from where the sample was collected: 3432984
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-02-22-60-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/23/2023
Date Tested: 03/22/2023
Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Organization Address: 21 Griffin Road North,
Organization City: Windsor
Organization State: CT
Organization Zipcode: 06095-1590
Organization Email: dlachaine@trccompanies.com
Organization Phone: (805) 621-3616
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.02 in
Average diameter of cylinder 2 4.01 in
Average diameter of cylinder 3 4.01 in
Cross sectional area of cylinder 1 12.69 in^2
Cross sectional area of cylinder 2 12.63 in^2
Cross sectional area of cylinder 3 12.63 in^2
Compressive strength (to nearest 10 psi) 7350 psi
Maximum load on cylinder 1 90360 lb
Maximum load on cylinder 2 98430 lb
Maximum load on cylinder 3 90030 lb
Compressive strength of cylinder 1 7120.6 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 7793.3 psi
Compressive strength of cylinder 3 7128.3 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 28 days
Age of specimen in hours 0 hours