Print Report | Back to Sample Detail

Sample Record for 2023-03-08-52

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK QA Service Level:
DIST-CO-RTE-PM: 59---
Work Description: Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-03-08-52
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (530) 329-6527
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 03/08/2023
Date that the sample was received by the laboratory/organization performing the testing: 03/17/2023
The quantity of what the sample constitutes: 208
A brief description of the sample: A449 Type 1
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Ameron International

Material Information

Rocap Number(s):
Heat Number(s): 3093332
Nut Mfg. Lot Number(s): NA
Washer Mfg. Lot Number(s): NA
Bolt Specification: A449
Bolt Length(s): 6
Nut Specification: NA
Washer Specification: NA
Finish: 64821-1
Diameter/Size: 0.625
Bolt Mfg. Lot Number: 64821-1
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test 1 of 1

DIME Test ID: 2023-03-08-52-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Verified Date: 03/29/2023
Date Tested: 03/21/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: F449 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Samples 1
SampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
1UNC 5/8 0.2263136713913879312969829312F449 Wedge Tensile
UTM 400kip
Temperature 72