Gavin Newsom, Governor |
DEPARTMENT OF TRANSPORTATIONDIVISION OF ENGINEERING SERVICES MATERIALS ENGINEERING AND TESTING SERVICES Concrete Materials Testing Branch 5900 Folsom Blvd. Sacramento, CA 95819 916-227-7205 |
Contract # 042908E4 Cty ALA Rte 580 PM 14.6/21.6 Vendor # |
REPORT OF LABORATORY TESTING |
||||
Resident Engineer: |
Satinder Grewal |
Date Reported: |
09/11/2015 |
|
Address: |
TL Number: |
207334 |
||
City: |
||||
Project Name: ROADWAY WIDENING AND REHABILITATION |
||||
Prime Contractor: DESILVA GATES CONSTRUCTION |
||||
Sample Taken Date: |
09/04/2015 |
Mix Design: |
unknown |
|
Contractor: Unknown |
Location: ALAMEDA COUNTY IN LIVERMORE, PLEASANTON, AND DUBLIN FROM 0.3 MILE EAST OF AIRWAY BOULEVARD OVERCROSSING TO 0.2 MILE WEST OF SAN RAMON/FOOTHILL ROAD OVERCROSSING |
|||
Structure unique identifier: Unknown |
||||
Structure name: Unknown |
||||
Location of Pour: Unknown |
The following testing has been tested in accordance with:
ASTM C39-17a : Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Specimen | Average diameter of cylinder (in) | Cross sectional area of cylinder (in^2) | Maximum load on cylinder (lb) | Compressive strength of cylinder (psi) | Type of fracture pattern of cylinder |
---|---|---|---|---|---|
1 | 6.01 | 28.37 | 86279 | 3041.2 | 1 |
2 | 6.01 | 28.37 | 89726 | 3162.7 | 1 |
DIME Test ID: 2015-09-04-2-1
Number of specimens: 2
Compressive strength (to nearest 10 psi): 3100
Comment on any defect in either specimen or caps (Max 250 Characters):
Age of specimen: 7 days
Certified By: Mike Mullins
*Subject to final inspection by the Resident Engineer. |
TL- Report of Laboratory Testing