Print Report | Back to Sample Detail

Sample Record for 2023-02-27-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 99999 DEA: 0322222 QA Service Level:
DIST-CO-RTE-PM: 03-SAC,OMG-888,99,80-0.6-0.6
Work Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location Description: THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Michael Maksimovich Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-02-27-1
TL Number from the TL Form:
Sample Submitted By Organization: CT D01 - Crescent City Field Laboratory
Sample Organization Contact: (707) 496-5581
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 02/27/2023
Date that the sample was received by the laboratory/organization performing the testing: 02/28/2023
The quantity of what the sample constitutes: 90 Cy
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Tidewater

Material Information

The concrete mix design number: unknown
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: unknown
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete Truck Chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-02-27-1-4
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/30/2023
Date Tested: 03/30/2023
Submitted By Organization: CT D01 - District 1 Materials Laboratory
Organization Address: 1726 Albee Street,
Organization City: Eureka
Organization State: CA
Organization Zipcode: 95501
Organization Email: leif.ayres@dot.ca.gov
Organization Phone: (707) 496-0974
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Cross sectional area of cylinder 1 28.3 in^2
Cross sectional area of cylinder 2 28.3 in^2
Compressive strength (to nearest 10 psi) 7260 psi
Maximum load on cylinder 1 195460 lb
Maximum load on cylinder 2 215470 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 28 days
Age of specimen in hours 0 hours

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-02-27-1-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders02/27/202303/06/2023Leif AyresCT D01 - Crescent City Field Laboratory 7 day breakLee Renick
2023-02-27-1-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders02/27/202302/27/2023Leif AyresCT D01 - District 1 Materials Laboratory
2023-02-27-1-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders03/30/202304/13/2023Leif AyresCT D01 - District 1 Materials LaboratoryDarla Ghidinelli