Print Report | Back to Sample Detail

Sample Record for 2023-02-22-8

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215317 DEA: 101J0104 EFIS: 1018000079 QA Service Level: 1
DIST-CO-RTE-PM: 10-CAL,CAL-88,34-34.6/2.2
Work Description: Construct fuel island canopies.
Location Description: In Calaveras and Alpine counties on Route 26 at the West Point Maintenance Station and on Route 88 at the Caples Lake Maintenance Station.
Contractor Name: CAL ELECTRO, INC. - Valerie Jenkins
Contractor Address: 3710 Electro Way, Redding, CA 96002
Resident Engineer: Pawan Garg Structure Rep.: Brandon Thurber

Sample Information

DIME Sample ID: 2023-02-22-8
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Acceptance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/22/2023
Date that the sample was received by the laboratory/organization performing the testing: 02/23/2023
The quantity of what the sample constitutes: 108
A brief description of the sample: 3/4 x 2 1/4" A325
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: CK Johnson

Material Information

Rocap Number(s): na
Heat Number(s): 1000213923
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A325
Bolt Length(s): 2 1/4"
Nut Specification: na
Washer Specification: na
Finish: hdg
Diameter/Size: 3/4
Bolt Mfg. Lot Number: 463453C
Rocap Test Requirement(s): no
Lubricant Requirements(s):

Test Results

Test 1 of 6

DIME Test ID: 2023-02-22-8-1
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/06/2023
Date Tested: 02/28/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 463453C
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 USA N
Size .75 in
Bolt Length 2.25 in
Gage Type Pass

Test 2 of 6

DIME Test ID: 2023-02-22-8-2
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/06/2023
Date Tested: 02/28/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 463453C
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 USA N
Size .75 in
Bolt Length 2.25 in
Gage Type Pass

Test 3 of 6

DIME Test ID: 2023-02-22-8-3
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/06/2023
Date Tested: 02/28/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 463453C
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 USA N
Size .75 in
Bolt Length 2.25 in
Measurement Average 3.35 mils

Test 4 of 6

DIME Test ID: 2023-02-22-8-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/06/2023
Date Tested: 02/28/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 463453C
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 USA N
Size .75 in
Bolt Length 2.25 in
Measurement Average 5.45 mils

Test 5 of 6

DIME Test ID: 2023-02-22-8-5
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/06/2023
Date Tested: 02/28/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 463453C
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 USA N
Size .75 in
Bolt Length 2.25 in
Hardness Reading Scale C Scale
Hardness Reading Average 29.27
Spacing Ok

Test 6 of 6

DIME Test ID: 2023-02-22-8-6
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/06/2023
Date Tested: 02/28/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No. 1B
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 463453C
Finish Coating ASTM F2329 - Hot Dip
Product Markings A325 USA N
Size .75 in
Bolt Length 2.25 in
Hardness Reading Scale C Scale
Hardness Reading Average 26.97
Spacing Ok