Print Report | Back to Sample Detail

Sample Record for 2023-01-20-47

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993511 DEA: 120R2004 EFIS: 1218000065 QA Service Level: 1
DIST-CO-RTE-PM: 12-ORA-5-0.0/2.0
Work Description: PLACE PRECAST CONCRETE PAVEMENT AND REPLACE CONCRETE SLAB.
Location Description: ORANGE COUNTY IN SAN CLEMENTE FROM ORANGE COUNTY LINE TO 0.4 MILE NORTH OF EL CAMINO REAL UNDERCROSSING
Contractor Name: Myers & Sons (SBE)
Contractor Address: 2554 Millcreek Drive, Sacramento, CA 95833
Resident Engineer: Mona Shahidi Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2023-01-20-47
TL Number from the TL Form:
Sample Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Sample Organization Contact: (909) 793-7602
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 01/20/2023
Date that the sample was received by the laboratory/organization performing the testing: 01/23/2023
The quantity of what the sample constitutes: 8
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: ProCast Products

Material Information

The concrete mix design number: RRM14062
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: TT
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Concrete sample from wheelbarrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 4

DIME Test ID: 2023-01-20-47-1
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Verified Date: 02/21/2023
Date Tested: 01/20/2023
Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Organization Address: 27417 East Third Street, P.O. Box 602
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: miker@procast.us
Organization Phone: (909) 557-3336
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Temperature 65 F

Test 2 of 4

DIME Test ID: 2023-01-20-47-2
Test Method: ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement Concrete
Verified Date: 02/21/2023
Date Tested: 01/20/2023
Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Organization Address: 27417 East Third Street, P.O. Box 602
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: miker@procast.us
Organization Phone: (909) 557-3336
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Slump 8.5 inch

Test 3 of 4

DIME Test ID: 2023-01-20-47-3
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 02/21/2023
Date Tested: 02/17/2023
Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Organization Address: 27417 East Third Street, P.O. Box 602
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: miker@procast.us
Organization Phone: (909) 557-3336
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Average diameter of cylinder 1 6.00 in
Average diameter of cylinder 2 6.00 in
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Cross sectional area of cylinder 1 28.27 in^2
Cross sectional area of cylinder 2 28.27 in^2
Compressive strength (to nearest 10 psi) 7110 psi
Maximum load on cylinder 1 192130 lb
Maximum load on cylinder 2 209480 lb
Type of fracture pattern of cylinder 1 2
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 0
Correction factor for cylinder 2 0
Age of specimen 28 days
Age of specimen in hours 0 hours

Test 4 of 4

DIME Test ID: 2023-01-20-47-4
Test Method: ASTM C138-17a: Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
Verified Date: 02/21/2023
Date Tested: 01/20/2023
Submitted By Organization: Pro-Cast Products, Incorporated - Highland
Organization Address: 27417 East Third Street, P.O. Box 602
Organization City: Highland
Organization State: CA
Organization Zipcode: 92346
Organization Email: miker@procast.us
Organization Phone: (909) 557-3336
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Identification of concrete represented by the sample RRM14062
Volume of the measure 0.249 ft^3
Density of concrete 145.8 lb/ft^3
Yield of concrete no data
Relative yield of the batch no data
Cement content no data
Air content no data