Print Report | Back to Sample Detail

Sample Record for 2015-08-19-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 209920 DEA: 072W5404 EFIS: 0713000206 QA Service Level: 1
DIST-CO-RTE-PM: 07-KER-5725-
Work Description: CONSTRUCT WASH BUILDING FACILITY.
Location Description: KERN COUNTY IN LEBEC AT THE LEBEC MAINTENANCE STATION AT 1586 LEBEC SERVICE ROAD
Contractor Name: GEMS ENVIRONMENTAL MANAGEMENT SERVICES, INC.
Contractor Address: 1120 Willow Pass Ct., Corcord, CA 94520
Resident Engineer: Efraim Chavez Structure Rep.: Paramananthan Piratheepan

Sample Information

DIME Sample ID: 2015-08-19-5
TL Number from the TL Form: 2W5404 2
Sample Submitted By Organization: CT - Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Control
Type of Material: Concrete
Sample Taken Date: 08/19/2015
Date that the sample was received by the laboratory/organization performing the testing: 08/24/2015
The quantity of what the sample constitutes: 2
A brief description of the sample: 6X12
From where was the sample collected: Job Site
Laboratory sample identification: 917-2
Structure unique identifier: 1586 LEBEC SERVICE RD LEBEC CA
Structure name: BLDG STEM AND WALL FOOTING
The fabricator/manufacturer/facility name: JOB

Material Information

The concrete mix design number: RD CLASS2
The truck number from where the sample was collected: A108
The batch plant ticket number from where the sample was collected: 21637
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: CHUTE
Where the material sample would have been placed if not sampled: Unknown
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2015-08-19-5-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/16/2015
Date Tested: 09/16/2015
Submitted By Organization: CT - Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 213-792-4794
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.02 in
Average diameter of cylinder 2 6.02 in
Cross sectional area of cylinder 1 28.46 in^2
Cross sectional area of cylinder 2 28.46 in^2
Compressive strength (to nearest 10 psi) 3670 psi
Maximum load on cylinder 1 102400 lb
Maximum load on cylinder 2 106370 lb
Compressive strength of cylinder 1 3598.0 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 3737.5 psi
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 no data
Age of specimen 28 days
Age of specimen in hours no data

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.