Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 214590 DEA: 043G4744 EFIS: 0412000074
QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN,MRN-580-6.9/7.8,0.0/2.5
Work Description: CLEAN AND PAINT STRUCTURAL STEEL BRIDGE.
Location Description: CONTRA COSTA AND MARIN COUNTIES IN RICHMOND AND SAN RAFAEL FROM 0.8 MILE WEST OF TOLL PLAZA TO 0.1 MILE EAST OF MAIN STREET
Contractor Name: Allied Painting, INC.
Contractor Address: 4 Larwin Road, Cherry Hill, NJ08034
Resident Engineer: Behzad Halali Structure Rep.: William Sommer
DIME Sample ID: 2023-02-07-31
TL Number from the TL Form:
Sample Submitted By Organization: CT SC - 3672 - Richmond
Sample Organization Contact: (510) 231-7108
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 02/07/2023
Date that the sample was received by the laboratory/organization performing the testing: 02/22/2023
The quantity of what the sample constitutes: 19
A brief description of the sample: A325 HDG Rocap Assembiy
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier: 28-0100
Structure name: Richmond San Rafael Bridge
The fabricator/manufacturer/facility name: Lejune
Rocap Number(s): 3417-02
Heat Number(s): Bolt 10769580
Nut 8000014475
Washer 32028550
Nut Mfg. Lot Number(s): 472199B
Washer Mfg. Lot Number(s): 167117
Bolt Specification: A325
Bolt Length(s): 3"
Nut Specification: A563
Washer Specification: F436
Finish: HDG
Diameter/Size: 7/8-9
Bolt Mfg. Lot Number: E255FI
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2023-02-07-31-1
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Verified Date: 03/06/2023
Date Tested: 03/01/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A325 Wedge Tensile
Test Result Compliance:
Additional Comments When Verified:
Number of Bolt Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By | 1A | E255F1 | 0.8750 | 67611 | 300.75 | 10.00 | A325 Wedge Tensile | rmacias |
| |
UTM
|
450kip
|
Temperature
|
no data
|
DIME Test ID: 2023-02-07-31-2
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Verified Date: 03/06/2023
Date Tested: 03/02/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test: A563 Nut Proof
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By | 1A | | | 72240 | | A563 Nut Proof | |
| |
UTM
|
450kip
|
Temperature
|
72 f
|
DIME Test ID: 2023-02-07-31-3
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/06/2023
Date Tested: 03/02/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E255F1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
0.875 in
|
Bolt Length
|
3 in
|
Gage Type
|
Pass
|
DIME Test ID: 2023-02-07-31-4
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Verified Date: 03/06/2023
Date Tested: 03/02/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
472199B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
0.875 in
|
Gage Type
|
Pass
|
DIME Test ID: 2023-02-07-31-5
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/06/2023
Date Tested: 03/02/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
E255F1
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
A325 LE USA
|
Size
|
0.875 in
|
Bolt Length
|
3 in
|
Measurement Average
|
2.97 mils
|
DIME Test ID: 2023-02-07-31-6
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/06/2023
Date Tested: 03/02/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
472199B
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
DH N
|
Size
|
0.875 in
|
Bolt Length
|
no data in
|
Measurement Average
|
3.99 mils
|
DIME Test ID: 2023-02-07-31-7
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/06/2023
Date Tested: 03/02/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
167117
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
B
|
Size
|
0.875 in
|
Bolt Length
|
no data in
|
Measurement Average
|
2.97 mils
|
DIME Test ID: 2023-02-07-31-8
Test Method: ASTM E18-20: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Verified Date: 03/06/2023
Date Tested: 03/02/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
167117
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
B
|
Size
|
0.875 in
|
Bolt Length
|
no data in
|
Hardness Reading Scale
|
C Scale
|
Hardness Reading Average
|
38.17
|
Spacing
|
Ok
|