Project Information

Project ID: 993490 DEA: 051M4604 EFIS: 0519000154 QA Service Level: 1
DIST-CO-RTE-PM: 05-MON-1-44.5
Work Description: CONSTRUCT RETAINING WALL, WIDENING SHOULDER AND PLACE HMA. Highway 1 at Coastlands Rd Soldier Pile Wall.
Location Description: MONTEREY COUNTY NEAR BIG SUR AT 1.0 MILE SOUTH OF PFEIFFER CANYON BRIDGE
Contractor Name: FEC Future Contractors & Engineers, Inc
Contractor Address: 184 Technology Dr., Ste 2, Irvine, CA 92618
Resident Engineer: Arashdeep Pannu Structure Rep.: Alex Naime

Sample Information

DIME Sample ID: 2023-02-06-6
TL Number from the TL Form: 213676
Sample Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Sample Organization Contact: 831-818-0254
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 02/06/2023
Date that the sample was received by the laboratory/organization performing the testing: 02/07/2023
The quantity of what the sample constitutes: 6 4x8s
A brief description of the sample: Cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name: Coastlands Wall
The fabricator/manufacturer/facility name: Granite Rock Sand City

Material Information

The concrete mix design number: 572590R
The truck number from where the sample was collected: 2433
The batch plant ticket number from where the sample was collected: 186070
Concrete batch plant: GR Sand City
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2023-02-06-6-2
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 03/22/2023
Date Tested: 03/20/2023
Submitted By Organization: CT D05 - Monterey Construction Field Laboratory
Organization Address: 1529 Salinas Highway,
Organization City: Monterey
Organization State: CA
Organization Zipcode: 93940
Organization Email: wesley.rider@dot.ca.gov
Organization Phone: (831) 818-0254
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.02 in
Average diameter of cylinder 2 4.02 in
Average diameter of cylinder 3 4.03 in
Cross sectional area of cylinder 1 12.69 in^2
Cross sectional area of cylinder 2 12.69 in^2
Cross sectional area of cylinder 3 12.76 in^2
Compressive strength (to nearest 10 psi) 6020 psi
Maximum load on cylinder 1 77570 lb
Maximum load on cylinder 2 77950 lb
Maximum load on cylinder 3 74150 lb
Type of fracture pattern of cylinder 1 1
Type of fracture pattern of cylinder 2 1
Type of fracture pattern of cylinder 3 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 42 days
Age of specimen in hours 0 hours

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2023-02-06-6-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders02/06/202303/06/2023Carson SperberCT D05 - Monterey Construction Field LaboratoryWesley Rider