Sample Record for 2022-12-21-81

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 215753 DEA: 050N72U4 EFIS: 0520000169 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-101-4.4/R7.7
Work Description: Please cc Office Engineer Ni Nyoman Paul on reports sent to RE and SR. Construct High Occupancy Vehicle (HOV) lanes on U.S. Route 101 and rehabilitation - Segment 4B.
Location Description: 101 freeway in Summerland, CA
Contractor Name: GRANITE CONSTRUCTION COMPANY
Contractor Address: 5335 Debbie Road, Santa Barbara, CA 93111
Resident Engineer: Luobao Cai Structure Rep.: Emiliano Berntsen

Sample Information

DIME Sample ID: 2022-12-21-81
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Sample Organization Contact: (805) 621-3616
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/21/2022
Date that the sample was received by the laboratory/organization performing the testing: 02/01/2023
The quantity of what the sample constitutes: 190 Cy
A brief description of the sample: concrete
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Martin Marietta Goleta

Material Information

The concrete mix design number: 72F1S0Z
The truck number from where the sample was collected: 675
The batch plant ticket number from where the sample was collected: 3432568
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-12-21-81-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 02/02/2023
Date Tested: 02/01/2023
Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Organization Address: 21 Griffin Road North,
Organization City: Windsor
Organization State: CT
Organization Zipcode: 06095-1590
Organization Email: dlachaine@trccompanies.com
Organization Phone: (805) 621-3616
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1 4.03 in
Average diameter of cylinder 2 4.04 in
Average diameter of cylinder 3 4.04 in
Cross sectional area of cylinder 1 12.76 in^2
Cross sectional area of cylinder 2 12.82 in^2
Cross sectional area of cylinder 3 12.82 in^2
Compressive strength (to nearest 10 psi) 7870 psi
Maximum load on cylinder 1 101190 lb
Maximum load on cylinder 2 101030 lb
Maximum load on cylinder 3 100170 lb
Compressive strength of cylinder 1 7930.3 psi
Type of fracture pattern of cylinder 1 5
Compressive strength of cylinder 2 7880.7 psi
Compressive strength of cylinder 3 7813.6 psi
Type of fracture pattern of cylinder 2 3
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 42 days
Age of specimen in hours 0 hours