Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 215351 DEA: 101C8004 EFIS: 1015000037
QA Service Level: 1
DIST-CO-RTE-PM: 10-SJ-4-0/0
Work Description: REPLACE MECHANICAL AND ELECTRICAL MOVEABLE BRIDGE EQUIPMENT.
Location Description: SAN JOAQUIN COUNTY NEAR DISCOVERY BAY AT OLD RIVER SR4 BRIDGE
Contractor Name: CALIFORNIA ENGINEERING CONTRACTORS, INC.
Contractor Address: 20 Happy Valley Road, Pleasanton, CA 94566
Resident Engineer: Ranbir Bhullar Structure Rep.: Daniel Laureno
DIME Sample ID: 2023-01-23-10
TL Number from the TL Form:
Sample Submitted By Organization: CT HQ - QASI Sacramento Field Office
Sample Organization Contact: (916) 2058871
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 01/23/2023
Date that the sample was received by the laboratory/organization performing the testing: 02/22/2023
The quantity of what the sample constitutes: 5
A brief description of the sample: 1 1/4" AB F1554 Gr 36
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor
Rocap Number(s):
Heat Number(s): 120104246820
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: F1554 Gr 36
Bolt Length(s): 16"
Nut Specification: na
Washer Specification: na
Finish: HDG
Diameter/Size: 1.25"
Bolt Mfg. Lot Number: unknown
Rocap Test Requirement(s):
Lubricant Requirements(s):
DIME Test ID: 2023-01-23-10-1
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 03/13/2023
Date Tested: 03/07/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 1 | 120104246820 | 0.494 | 0.192 | 49416 | 70678 | 32.6 | rmacias |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
DIME Test ID: 2023-01-23-10-2
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 03/13/2023
Date Tested: 03/07/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Number of Samples
|
1
|
Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By | 2 | 120104246820 | 0.497 | 0.194 | 50389 | 70312 | 34.4 | rmacias |
| |
UTM
|
67kip
|
Temperature
|
72 f
|
DIME Test ID: 2023-01-23-10-3
Test Method: ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Verified Date: 03/13/2023
Date Tested: 03/07/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
120104246820
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BLUE
|
Size
|
1.25 in
|
Bolt Length
|
16 in
|
Gage Type
|
Pass
|
DIME Test ID: 2023-01-23-10-4
Test Method: ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 03/13/2023
Date Tested: 03/07/2023
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Boulevard,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: joshua.moore@dot.ca.gov
Organization Phone: (530) 329-6527
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Sample No.
|
1A
|
Rocap Number
|
no data
|
Heat Number(s)
|
no data
|
Mfg. Lot Number
|
120104246820
|
Finish Coating
|
ASTM F2329 - Hot Dip
|
Product Markings
|
BLUE
|
Size
|
1.25 in
|
Bolt Length
|
16 in
|
Measurement Average
|
6.52 mils
|