Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 994092 DEA: 07339204 EFIS: 0717000119
QA Service Level: 1
DIST-CO-RTE-PM: 07-VEN-118-0.7/11.0
Work Description: REPLACE MINOR CONCRETE CURB RAMPS & MODIFY SIGNAL & LIGHTING SYSTEMS.
Location Description: VENTURA COUNTY IN AND NEAR OXNARD FROM DARLING ROAD TO ROUTE 34/118 SEPARATION
Contractor Name: Toro Enterprise
Contractor Address: 2101 E Ventura BLVD, Oxnard, CA 93036
Resident Engineer: Denrick Bautista Structure Rep.: Unknown
DIME Sample ID: 2023-01-19-12
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Sample Organization Contact: (213) 817-0387
Type of Sample: Acceptance
Type of Material: Soil
Sample Taken Date: 01/19/2023
Date that the sample was received by the laboratory/organization performing the testing: 01/20/2023
The quantity of what the sample constitutes: 150 SF
A brief description of the sample: Subgrade
From where was the sample collected: Job Site
Laboratory sample identification: 23-0043
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: NA
The fabricator's/manufacturer's product name for the sample: Subgrade
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Various locations
Where the material sample would have been placed if not sampled:
DIME Test ID: 2023-01-19-12-1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Verified Date: 01/20/2023
Date Tested: 01/19/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test: VEN Rte. 118
ADA Ramp - Location #10
North of Violeta St. and W Los Angeles Ave (118)
Test Result Compliance:
Additional Comments When Verified:
Standard Count Density
|
2335 g/cc
|
Count or Density 1
|
2.01 g/cc
|
Count or Density 2
|
2.05 g/cc
|
Count or Density 3
|
1.95 g/cc
|
Standard Count Moisture
|
643 g/cc
|
Moisture Count 1
|
0.18 g/cc
|
Moisture Count 2
|
0.16 g/cc
|
Moisture Count 3
|
0.22 g/cc
|
Sum of Count or Density
|
6.01 g/cc
|
Average of Count or Density
|
2.00 g/cc
|
Sum of Moisture Count
|
0.56 g/cc
|
Average of Moisture Count
|
0.19 g/cc
|
Calculated Percent Relative Compaction
|
92.3 %
|
Reported Percent Relative Compaction
|
92 %
|
DIME Test ID: 2023-01-19-12-2
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Verified Date: 01/20/2023
Date Tested: 01/19/2023
Submitted By Organization: CT D07 - Materials Field Laboratory, Unit 1953
Organization Address: 1940 South Workman Mill Road,
Organization City: Whittier
Organization State: CA
Organization Zipcode: 90601
Organization Email: chad.chotibhongs@dot.ca.gov
Organization Phone: (213) 817-0387
General Comments for this Test: VEN Rte. 118
ADA Ramp - Location #10
North of Violeta St. and
W Los Angeles Ave (118)
Test Result Compliance:
Additional Comments When Verified:
Is oversize material
|
No
|
In-place wet density
|
2.00
|
Highest adjust wet density
|
2.17
|
Relative compaction
|
92
|
% Moisture
|
10.3 %
|
Optimum Moisture
|
no data
|