Sample Record for 2022-12-01-25
Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project Information
Project ID: 211260 DEA: 072159U4 EFIS: 0715000160
QA Service Level: 1
DIST-CO-RTE-PM: 07-LA,ORA-5-0.0/1.5, 44.3/44.4
Work Description: CONSTRUCT HOV LANES AND MIX FLOW LANES.
Location Description: LOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 3075 TOWNSGATE RD. SUITE 200, WESTLAKE VILLAGE, CA 91361
Resident Engineer: George Saker Structure Rep.: Danny Lalonde
Sample Information
DIME Sample ID: 2022-12-01-25
TL Number from the TL Form:
Sample Submitted By Organization: CT D07 - Plant Services
Sample Organization Contact: 562-345-3126
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 12/01/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/05/2022
The quantity of what the sample constitutes: 400 tons
A brief description of the sample: 3/4 HMA-SP Type A
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Vulcan Irwindale
Material Information
Source Identification (SMARA, name of Pit or Job Site): 91-19-0035
The fabricator's/manufacturer's product name for the sample:
The fabricator/manufacturer designation for the sample:
The plant number: Irwindale
A detailed description of where the material sample was collected: Belt Discharge
Where the material sample would have been placed if not sampled:
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: 220817A IRW SJR
Lot number:
Sublot number:
Aggregate Mix Number:
Test Results
Test 1 of 3
DIME Test ID: 2022-12-01-25-1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Verified Date: 01/05/2023
Date Tested: 12/06/2022
Submitted By Organization: CT D07 - Plant Services
Organization Address: 13230 East Firestone Boulevard, Suite G,
Organization City: Santa Fe Springs
Organization State: CA
Organization Zipcode: 90670
Organization Email: victor.zengler@dot.ca.gov
Organization Phone: (562) 345-3126
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
What type of gradation is being tested?
|
HMA Gradation
|
Cumulative percent passing the 1 1/2 in. sieve
|
100 %
|
Cumulative percent passing the 1 in. sieve
|
100 %
|
Cumulative percent passing the 3/4 in. sieve
|
96 %
|
Cumulative percent passing the 1/2 in. sieve
|
78 %
|
Cumulative percent passing the 3/8 in. sieve
|
67 %
|
Cumulative percent passing the #4 sieve
|
45 %
|
Cumulative percent passing the #8 sieve
|
33 %
|
Cumulative percent passing the #16 sieve
|
21 %
|
Cumulative percent passing the #30 sieve
|
14 %
|
Cumulative percent passing the #50 sieve
|
8 %
|
Cumulative percent passing the #100 sieve
|
5 %
|
Cumulative percent passing the #200 sieve
|
3.7 %
|
Test 2 of 3
DIME Test ID: 2022-12-01-25-2
Test Method: AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Verified Date: 01/05/2023
Date Tested: 12/06/2022
Submitted By Organization: CT D07 - Plant Services
Organization Address: 13230 East Firestone Boulevard, Suite G,
Organization City: Santa Fe Springs
Organization State: CA
Organization Zipcode: 90670
Organization Email: victor.zengler@dot.ca.gov
Organization Phone: (562) 345-3126
General Comments for this Test:
Test Result Compliance: not applicable
Additional Comments When Verified:
Which test procedure is being used
|
Method A
|
Percent of sample passing the #200 sieve (by mass)
|
8.2 %
|
Test 3 of 3
DIME Test ID: 2022-12-01-25-3
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 01/05/2023
Date Tested: 12/06/2022
Submitted By Organization: CT D07 - Plant Services
Organization Address: 13230 East Firestone Boulevard, Suite G,
Organization City: Santa Fe Springs
Organization State: CA
Organization Zipcode: 90670
Organization Email: victor.zengler@dot.ca.gov
Organization Phone: (562) 345-3126
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified: