Print Report | Back to Sample Detail

Sample Record for 2022-12-05-46

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 993235 DEA: 051H4504 EFIS: 0516000075 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-154-R31.8/R32.1
Work Description: CONSTRUCT CIDH CONCRETE PILES AND STRUCTURAL CONCRETE BRIDGE.
Location Description: SANTA BARBARA COUNTY IN AND NEAR SANTA BARBARA FROM PRIMAVERA ROAD UNDERCROSSING TO LA COLINA ROAD UNDERCROSSING
Contractor Name: CA Rasmussen
Contractor Address: 28548 LIVINGSTON AVENUE, VALENICA CA 91355
Resident Engineer: Jeffery Finn Structure Rep.: Emiliano Berntsen

Sample Information

DIME Sample ID: 2022-12-05-46
TL Number from the TL Form:
Sample Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Sample Organization Contact: (805) 621-3616
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 12/05/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/13/2022
The quantity of what the sample constitutes: 120 CY
A brief description of the sample: 4x8 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Cemex

Material Information

The concrete mix design number: 1626524
The truck number from where the sample was collected: 10067301
The batch plant ticket number from where the sample was collected: 30560828
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Discharge from concrete truck into wheelbarrow.
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test 1 of 1

DIME Test ID: 2022-12-05-46-1
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Verified Date: 01/03/2023
Date Tested: 12/13/2022
Submitted By Organization: CT D05 - Carpinteria Field Laboratory
Organization Address: 21 Griffin Road North,
Organization City: Windsor
Organization State: CT
Organization Zipcode: 06095-1590
Organization Email: dlachaine@trccompanies.com
Organization Phone: (805) 621-3616
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 3
Test performed With no density determined
Capped in accordance with? ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1 4.00 in
Average diameter of cylinder 2 4.00 in
Average diameter of cylinder 3 4.00 in
Cross sectional area of cylinder 1 12.57 in^2
Cross sectional area of cylinder 2 12.57 in^2
Cross sectional area of cylinder 3 12.57 in^2
Compressive strength (to nearest 10 psi) 8390 psi
Maximum load on cylinder 1 105580 lb
Maximum load on cylinder 2 104700 lb
Maximum load on cylinder 3 106070 lb
Compressive strength of cylinder 1 8399.4 psi
Type of fracture pattern of cylinder 1 3
Compressive strength of cylinder 2 8329.4 psi
Compressive strength of cylinder 3 8438.3 psi
Type of fracture pattern of cylinder 2 5
Type of fracture pattern of cylinder 3 5
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Correction factor for cylinder 3 1
Age of specimen 7 days
Age of specimen in hours 0 hours