Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.
Project ID: 993651 DEA: 112N1144 EFIS: 1121000143
QA Service Level: 1
DIST-CO-RTE-PM: 11-IMP-78-34.0/41.0
Work Description: COLD IN-PLACE RECYCLING, RHMA-G OVERLAY, PAVEMENT MARKINGS.
Location Description: IMPERIAL COUNTY NEAR AND AT GLAMIS FROM 6.7 MILES EAST OF EAST HIGHLINE CANAL TO TED KIPF ROAD
Contractor Name: HAZARD CONSTRUCTION
Contractor Address: 10529 Vine Street, Lakeside, CA 92040
Resident Engineer: Daniel Hernandez Duarte Structure Rep.: Unknown
DIME Sample ID: 2022-12-14-21
TL Number from the TL Form: C004854
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Acceptance
Type of Material: Asphalt Rubber Binder
Sample Taken Date: 12/14/2022
Date that the sample was received by the laboratory/organization performing the testing: 12/22/2022
The quantity of what the sample constitutes: 1 Quart Can
A brief description of the sample: Asphalt Rubber Binder
From where was the sample collected: Supplier
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: APZ Rubber Plant
Asphalt modifier supplier:
Performance Grade: PG 64-16
Lot number:
Sublot number:
Asphalt Rubber Binder Mix Number:
DIME Test ID: 2022-12-14-21-1
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Verified Date: 05/30/2023
Date Tested: 12/29/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: does not comply
Additional Comments When Verified:
ASTM Thermometer used?
|
C
|
Softening Point Sample 1
|
75 C
|
Softening Point Sample 2
|
75 C
|
Bath Liquid
|
freshly boiled distilled water
|
Minutes Reaction
|
no data
|
DIME Test ID: 2022-12-14-21-2
Test Method: ASTM D217-16: Standard Test Methods for Cone Penetration of Lubricating Grease (Cone Penetration)
Verified Date: 05/30/2023
Date Tested: 12/30/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Determination
|
Unworked Penetration
|
Unworked Penetration
|
25 0.1 mm
|
DIME Test ID: 2022-12-14-21-3
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Verified Date: 05/30/2023
Date Tested: 12/30/2022
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance: complies
Additional Comments When Verified:
Temperature
|
25 C
|
Final Dial reading (F1)
|
50 mm
|
Ball Penetration (P1)
|
0 mm
|
Final Dial reading (F2)
|
49 mm
|
Ball Penetration (P2)
|
0 mm
|
Final Dial reading (F3)
|
50 mm
|
Ball Penetration (P3)
|
0 mm
|
Resilience 1
|
50 %
|
Resilience 2
|
51 %
|
Resilience 3
|
50 %
|
Average Resilience
|
50 %
|
Minutes Reaction
|
no data
|